 THIS WING PREPARES BUILDING PLANS ON BASIS


OF THE SCOPE OF WORK SUPPLIED BY THE CLIENT
DEPTT.

 THE PLANNING OF THE BUILDING TO BE FINALIZED


AFTER DISCUSSIONS WITH THE CLIENT DEPTT.

 TO MEET OUT THE ALL REQUIREMENTS OF LOCAL


BUILDING BYE LAWS/NATIONAL BUILDING CODE
GENERAL DEFECTS IN PLANNING,FUNCTIONAL
UTILITES AND REQUIREMENTS OF USERS.

 PROPER PLACEMENT OF ROOMS AND CB


 PROPER PLACEMENT OF DOORS/WINDOWS
 STEPS AND HEAD WAY IN STAIRCASE
 WORKING SLAB HEIGHT IN KITCHEN
 FIXING OF INDIAN WC.
 WASHBASIN/URINALS HT. IN TOILETS
ARCHITECTURAL PLANNING

 FUNCTIONAL
 ASTHETICAL

 ECONOMICAL

 BARRIER FREE ENVIRONMENT

 AREAS AS PER GOVT. NORMS

 DISASTER MANAGEMENT PARAMETERS:- SEISMIC,


FIRE, FLOOD
 STATUTORY APPROVALS .
SITE DEVELOPMENT

 PLINTH LEVEL OF THE BUILDING FROM NGL/OUTER


ROAD.
 SITE APPROACH ROAD
 STORM WATER DISPOSAL
 HORTICULTURE AND LANDSCAPING
 RAIN WATER HARVESTING
 INTERNAL ROAD NETWORK IN THE CAMPUS.
 SIGNAGE OF THE BUILDINGS
ESTATE SERVICES (PH & ELECT)

 PUBLIC HEALTH ENGINEERING:-


 LAYING OF PROPER SEWER LINES , WATER LINES AND
STROM WATER DISPOSAL
 LOCATION OF SEWERAGE TREATMENT PLANT
 ELECTRICAL ENGINEERING:-
 LAYING OF LT LINES IN THE CAMPUS
 LOCATION OF SUB STATION
 DG SET AND ELECTRIC TRANSFORMER
 PROVISIONS OF LED LIGHTS,SOLAR POWER PANELS
 FANS & FITTINGS ARE ENERGY EFFICIENT AS PER BEE
GUIDELINES.
RAIN WATER HARVESTING

 THE RAIN WATER OF THE ROOF AREA , SURFACE


RUN OFF COLLECTED AND RECHARGED INTO
GROUND.

 HELPS IN RAISING THE WATER TABLE.

 COLLECTED WATER CAN BE USED FOR LANDCAPING


AND FLUSHING IN TOILETS.
NEW BUILDING CONSTRUCTION MATERIALS

 SUBSTITUTE OF RED BRICKS SUCH AS AAC BLOCKS,


FLY ASH BRICKS, CONCREATE HOLLOW BLOCKS ETC.
 PRE FAB STRUCTURE AS PER REQUIREMENT OF SITE.
SUCH AS DRY WALL AND PRE- ENGINEERING
STRUCTURE
 READY MIXED CONCRETE
 EXTERNAL FINISHINGS SUCH AS HPL,TILES,STONE
CLADING ETC.
 GYP PLASTER
 UPVC FOR JOINERY WORK
GREEN BUILDING FEATURES

 ORIENTATION OF THE BUILDING


 AAC/FLY ASH BRICKS INSTEAD OF RED BRICKS
 SHADING DEVICES ON BUILDING
 CAVITY WALLS IN EAST AND WEST DIRECTION DUE
TO WORST ORIENTATION.
 COMPOSITE BUILDING MATERIALS SUCH AS MDF
BOARD AND COMMERRCIAL BOARD
 GREEN PAVERS
 PLANTATIONS AS PER ORIENTATIONS.
 PROVISION OF ECBC NORMS.
INNOVATIONS

DEPRESSED SLABS IN TOILETS AVOIDED


 DEPRESSED SLABS OF TOILETS ARE ALWAYS A
SOURCE OF LEAKAGE IN MOST OF THE BUILDINGS.
 NO DEPRESSED SLAB PROVIDED FOR C.I./PVC PIPES.

 ALL THE C.I./PVC PIPES ARE PROVIDED IN HANGING


IN OPEN BELOW SLAB. COVERED WITH WATER
PROOF FALSE CEINING CAN BE PROVIDED FOR
AESTHIC.
 DUE TO THIS PROVISION, IT IS EASY TO FIND ANY
LEAKAGE IN PIPES /JOINTS, IF OCCURS AS WELL AS
EASY TO REPAIR THE SAME.
HANGING PIPES BELOW SLAB FOR TOILETS
PROPER SLOPE IN TOP ROOF

RCC SLABS LAID IN 1:80 SLOPE


TREATMENT OF EXPANSION JOINT

 EXPANSION JOINT TO BE PROVIDED AS PER


STRUCTURAL REQUIREMENTS

 PROPER TREATMENT OF EXPANSION TO


ENSURE NO LEAKAGE.
DETAIL OF EXPANSION JOINT IN TOP ROOF
FIRE FIGHTING SYSTEM

 FIRE FIGHTING SYSTEM AS PER LATEST GUILDLINES


 SUFFICIENT MOTORABLE AREA AVAILABLE AROUND THE
BUILDING FOR FREE MOVEMENT OF FIRE TENDERS.
 YARD HYDRANT MUST BE ALL AROUND THE BUILDIND
AND FIRE BRRIGADE WATER CONNECTION AT GATE OF
THE SITE
 SPRINKLERS MUST BE IN BASEMENT AUTOMATICALLY
OPERATED WHEN THE TEMPERATURE RISES TO 650C
 FIRE ALARM & FIRE FIGHTING SYSTEM MUST BE AS PER
LATEST TECHNOLOGY & CODAL REQUIREMENTS
FIRE FIGHTING SYSTEM

 ADDRESSABLE FIRE ALARM SYSTEM


 IMMEDIATE ALARMING & LOCATION OF FIRE
OCCURRENCE DISPLAYED ON THE PANEL.
 HEAT & SMOKE DETECTORS
 PRESSURIZING SYSTEMS MUST BE IN LIFT WELLS
AND STAIRCASES.
 PROVISION OF HOLDING AREA IN FRONT OF THE
STAIRCASE AND REFUSE TERRACES AS PER
REQUIREMENTS
FIRE CONTROL PANEL
EQUIEPMENTS OF FIRE

FIRE ALARM SMOKE DETECTOR

WATER SPRINKLER IN BASEMENT FIRE EXTINGUISHER


EQUIPMENT OF FIRE

FIRE DUCT WITH HOSE REEL


STANDARD NORMS FOR PLANNING OF
HABITABLE ROOM

 MIN. AREA =9.5O SQ.M(102SFT)


 MIN. WIDTH OF ROOM =2.40M (8’-0”)
 MIN HEIGHT. = 2.75M (9’-0”)
 MIN. LIGHT VENTILATION =25% OF CARPET
AREA
 MIN DOOR OPENING =.91M (3’-0”)
PLANNING OF MIN. SIZE OF HABITABLE ROOM

DOUBLE BED=6’X6’

CHAIRS =2NOS

LOCATION OF LED
STANDARD PLANNING NORMS OF KITCHEN

COOKING AREA
MIN. AREA =5.5 SQ.M (60SFT)
MIN. WIDTH =1.80M (6’-0”)
MIN. HEIGHT. = 2.75M (9’-0”)
MIN. LIGHT VENTILATION =25% OF CARPET AREA
MIN DOOR OPENING =0.85M (2’-9”)
MAX.HT. OF THE WORKING TOP=0.85M(2’-9”)
MODEL OF KITCHEN

VIEW OF KITCHEN HEIGHT OF WORKING SHELF


STANDARD NORMS FOR PLANNING OF TOILETS

 TOILET
 MIN. AREA =2.80 SQ.M
 MIN. WIDTH =1.20M (4’-0”)
 MIN. HEIGHT. = 2.30M (7’-6”)
 MIN. LIGHT VENTILATION =25% OF
TOILET AREA WITH 0.20 PV
 MIN DOOR OPENING =0.76M (2’-6”)
 MAX. HT OF WHB =0.85M(2’-9”)
MODEL OF TOILET

VIEW OF TOILET PLAN OF TOILET


PLANNING OF HOUSE
HARYANA POLICE HOUSING CORPORATION LTD.

THANK YOU

ARCHITECTURE WING