You are on page 1of 22

SUG541

ADVANCED PHOTOGRAMMETRY

TITLE
STEP INVOLVED IN USING STEREO AERIAL
TRIANGULATION SOFTWARE
1. Launch Stereo
AT software

2. Create new
model
3. File Name – Put file name to create
4. Left Image – browse for the left image
5. Right Image – browse for the right image.
6. If the image is mistakenly selected for the left or right, the user can use
Swap Images to change from Left to right and otherwise
7. Create
INTERIOR ORIENTATION
1. START INTERIOR PROCESS WITH LEFT IMAGE AND THEN RIGHT
IMAGE

2. KEY IN THE CAMERA INFORMATION


INTERIOR ORIENTATION
3. Click fiducial point at every tip of the image.
RELATIVE ORIENTATION
1. After finished the Inner Orientation for the both left and right. User has
to do relative process for the selected model.
2. Select Orientation > Absolute
RELATIVE ORIENTATION
3. Select tie points on the image. Minimum 6 points with numbering for
each model
RELATIVE ORIENTATION

4. Click any position on the model


5. Do the process until RMS error in acceptable range limitation
6. Principal Point of Autocollimation
RELATIVE ORIENTATION

7. After all points have created, index window will appear


GROUND CONTROL POINT PROCESS

1. After finished the absolute orientation process,


user has to perform a GCP.
2. Identify the GCP position for each model and
create file for control point

3. Key in all the information (X, Y, Z) for each GCP


GROUND CONTROL POINT PROCESS

4. Click the GCP point on the model. Refer


to the image given which show the position
of the GCP

5. After finished GCP process for 6 GCP’s,


close the window
PREPARATION FOR ADJUSTMENT
1. Export Adjustment to Run Adjustment in AeroSys
2. Export file in .ptb format.
PREPARATION FOR ADJUSTMENT

2. Open the file that already


exports in .ptb format before

3. Edit the file until same with


below format that show
below

4. Save as the file as .ctl format


ADJUSTMENT USING AEROSYS SOFTWARE

1. Launch AeroSys. Open


a project

2. For the current project,


fill the appropriate
information at the
number 1

3. And for the number 2


load the saved .ctl file.
And Next
ADJUSTMENT USING AEROSYS SOFTWARE
4. After that, click Next button. Fill
the information on
‘Photocoordinate Type’ tab

5. At ‘Block Configuration’ tab,


load the file in .ptb format
ADJUSTMENT USING AEROSYS SOFTWARE

5. Then, Fill the information


on ‘Camera Data Base’ tab

6. After all, click Save and


OK
ADJUSTMENT USING AEROSYS SOFTWARE

8. Click RelOrn to run


the project. RelOrn
window will appear

9. Click Run on the


below
ADJUSTMENT USING AEROSYS SOFTWARE

11. The processing result will appear.


12. Click Next and Run until Mean Predicted Accuracy appear.
13. If there are problem on Relative process, Mean Predicted Accuracy
cannot done.
14. Please recheck the relative process so that Mean Predicted Accuracy
ADJUSTMENT USING AEROSYS SOFTWARE

12. After the Mean Predicted Accuracy is acceptable, close the window
ABSOLUTE ORIENTATION

1. Once the Aerosys


adjustment is finished, load
back the Stereo AT software.
2. Import the data that save in
AeroSys
3. After the done importing
data, Absolute is completed
DIGITIZING USING DVP SOFTWARE
1. Open DVP process. File and Open
Image
2. Create vector layer at vector manager
for different type of object that want to
digitize. Road, DEM and building
DIGITIZING USING DVP SOFTWARE
3.Using 3D view, start digitizing
4. Transfer to AutoCAD