You are on page 1of 78

OptiX RTN 600 Configuration

—Using the T2000 and T2000 Web LCT

www.huawei.com

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved.


Foreword
 Huawei provides NE-level, subnet-level and network-level management
systems for the RTN 600 series products.
 This course describes the NE-level management system OptiX iManager
T2000 Web LCT and the subnet-level management system OptiX iManager
T2000.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 2
Reference
 Digital Microwave Communication principles
 OptiX iManager T2000 Management System
Solution V2.31
 OptiX iManager T2000 Web LCT Installation
Guide and User Guide

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 3
Objectives
Upon completion of this course, you will be able to:
 Describe the functions of the T2000 and the T2000 Web LCT.

 Install the T2000 Web LCT.

 Configure services and protection by using the T2000 and the T2000
Web LCT.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 4
Contents
1. Introduction to Networks
Management Systems

2. Introduction to T2000 Web LCT

3. Introduction to the T2000

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 5
Comprehensive Management System
Solution
OSS or integrated
NMS Service
Integrated NMS & OSS CORBA management
layer
CORBA CORBA
iManager T2100
Network
iManager T2100
MML MML MML
management
layer
iManager T2000 iManager T2000 iManager T2000
iManager T2000 NE
LCT
Qx Qx Qx Qx management
layer

NE layer

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 6
Introduction to Management Systems
The orientation of each management system is as follows:
 iManager T2000 LCT
 The T2000 local craft terminal (LCT) realizes the local maintenance and equipment turn-
up of Huawei OptiX products.
 iManager T2000
 The iManager T2000 (T2000 for short) is a subnet management system (SNMS) for
transport networks. The T2000 manages the full series of Huawei OptiX products. The
T2000 supports all functions of the NE layer and some of the network layer management
functions.
 iManager T2100
 The iManager T2100 (T2100 for short) is a network-level management system that
uniformly manages the full series of Huawei OptiX products. It manages large-scale
optical transport networks in a uniform manner.
 iManager MDS
 The iManager MDS (MDS for short) is a business-level management system for
transport networks. It assists users to plan and simulate an optical transport network.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 7
Introduction to Management Systems
 Platforms where the management systems are
running

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 8
Contents
1. Introduction to Management Systems

2. Introduction to the T2000 Web LCT

3. Introduction to the T2000

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 9
Contents
 Introduction to the T2000
Web LCT
 2.1 Main Characteristics
 2.2 Application Scenario
 2.3 Installation Guide
 2.4 Connecting to NEs
 2.5 Configuration Operations

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 10
T2000 Web LCT – Main Characteristics
The characteristics of the T2000 Web LCT are as follows:
 Web-based solution
 Per-NE configuration and maintenance
 Access to a local NE through a LAN/RS 232
 Access to a remote NE through DCC
 Management of NEs of various types
 Concurrent login to a maximum of 32 NEs
 Integration with the T2000, T2100 or third-party
management system

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 11
T2000 Web LCT – Function
The T2000 Web LCT provides the following NE-layer management functions:
 Service configuration (including PDH and SDH microwave services)
 Protection configuration (intermediate frequency protection, SNCP, LMSP)
 Setting and query of the intermediate frequency attributes
 Setting and query of the radio frequency attributes
 Data services (the 10M/100M fast Ethernet transparent transmission b
oard EFT4 is supported)
 Setting and viewing of alarms and performance data
 Communication and security

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 12
Contents

Introduction to the T2000 Web LCT


 2.1 Main Characteristics
 2.2 Application Scenario
 2.3 Installation Guide
 2.4 Connecting to NEs
 2.5 Configuration Operations

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 13
T2000 Web LCT – Application Scenario
Stand-alone

 The equipment maintenance personnel installs the T2000


Web LCT on a PC.

 The equipment maintenance personnel manages local or


remote NEs by using the T2000 Web LCT.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 14
T2000 Web LCT – Application Scenario
Integrated
 The personnel at the network operations center install the EMS or NMS on a PC.
 Install the T2000 Web LCT as a part of the EMS. The NMS need not be installed.
 The personnel at the network operations center starts the T2000 Web LCT by
using the EMS or NMS client.

NMS

DCN
EMS
EMS

NE network NE network

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 15
Contents

 Introduction to the T2000 Web LCT


 2.1 Main Characteristics
 2.2 Application Scenario
 2.3 Installation Guide
 2.4 Connecting to NEs
 2.5 Configuration Operations

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 16
T2000 Web LCT – Installation Guide
Pre-installation
 Configuration requirements
 The T2000 Web LCT runs on the Windows operating system.
 Hardware requirements
 CPU: Pentium III 700 MHz or higher
 RAM: 256 MB (recommended 512 MB or higher)
 Monitor: 1024 x 768 resolution
 Serial port: RS 232
 Ethernet port: 10M/100M

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 17
T2000 Web LCT – Installation Guide
Pre-installation (continued)
 Software requirements
 Windows XP Professional SP2/Windows 2003

Server Standard SP1


 Internet Explorer 6.0 or better
 Tomcat 5.0
 JDK1.4.2
 Servlet 2.3

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 18
T2000 Web LCT – Installation Guide
 Prerequisite: Windows XP Professional SP2 or Windows 2003 Server standard SP1
must be installed.
 Procedure
 Step 1 Uncompress the installation package or Insert the installation CD-ROM,
and run the setup.exe file. Click Next.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 19
T2000 Web LCT – Installation Guide
 Step 2 Select I accept the terms of the license agreement and click Next.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 20
T2000 Web LCT – Installation Guide
 Step 3 Enter your user name, company name, and serial number Click
Next.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 21
T2000 Web LCT – Installation Guide
 Step 4 Click Next.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 22
T2000 Web LCT – Installation Guide
 Step 5 Click Install and the Setup Status dialog box is displayed. After the T2000 Web
LCT is installed, the Installation Complete dialog box is displayed.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 23
T2000 Web LCT – Installation Guide

 Step 6 Click Finish.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 24
T2000 Web LCT – Installation Guide
Checking the Installation

After you install the T2000 Web LCT, you need to check the correctness of
installation. Check directories and files as follows:
 The T2000 Web LCT installation directory.
 By default is C:\Web_LCT.
 The installation directory of the jre software.
 By default is C:\Web_LCT\jre.
 The installation directory of the Tomcat software.
 By default is C:\Web_LCT\Tomcat .
 Check the shortcut icon on desktop. The iManager T2000 Web LCT group is
created in the Windows Program bar.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 25
Contents
 Introduction to the T2000
Web LCT
 2.1 Main Characteristics
 2.2 Application Scenario
 2.3 Installation Guide
 2.4 Connecting to NEs
 2.5 Configuration Operations

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 26
T2000 Web LCT – Connecting to NEs
 To use the T2000 Web LCT to configure and manage NEs, you need to
connect the T2000 Web LCT to NEs with an Ethernet cable or a serial port.
 Procedure
 By using a network cable

1. Connect a network cable to the computer where the T2000 Web LCT
resides.

2. Route the network cable to the equipment side and connect the RJ-45
connector of the network cable to the network management interface
on the front panel of the equipment.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 27
T2000 Web LCT – Connecting to NEs
 Procedure (continued)
 By using DCN
1. Use a network cable to connect the computer where the T2000 Web LCT
resides to the DCN.
2. Connect one end of another network cable to the network management
interface on the front panel of the equipment. Connect another end to the
DCN.
 By using an RS 232 serial port cable
1. Connect the serial port cable to the computer where the T2000 Web LCT
resides.
2. Route the serial port cable to the equipment side. Connect the RS 232
connector of the serial port cable to the RS 232 interface on the front
panel of the equipment.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 28
Contents

 Introduction to the T2000 Web LCT


 2.1 Main Characteristics
 2.2 Application Scenario
 2.3 Installation Guide
 2.4 Connecting to NEs
 2.5 Configuration Operations

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 29
Contents
 Configuration Operations
 2.5.1 Logging In to an NE
 2.5.2 Modifying the NE ID
 2.5.3 Configuring IF Protection
 2.5.4 Setting IF Attributes
 2.5.5 Setting RF Attributes
 2.5.7 Configuring Service
 2.5.7 Configuring SNCP Service
 2.5.8 Converting service
 2.5.9 Alarm
 2.5.10 Performance
 2.5.11 Communications and Security

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 30
Web LCT Configuration – Logging In to an NE
Step1 Double-click the T2000 Web LCT shortcut icon on the desktop to launch the T2000
Web LCT.

Step2 The User Login screen is displayed. Enter the user name and password. Click Login.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 31
Web LCT Configuration – Logging In to an NE
Step3 Create an NE in one of the following two ways.

1. Click NE Search and specify the search criteria. Select the NE to be added to
create a new NE.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 32
Web LCT Configuration – Logging In to an NE

2. Create an NE directly. Click the “Add NE” and Enter the information of the
NE and create the NE.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 33
Web LCT Configuration – Logging In to an NE
 Step 4: In the NE List, select the target NE and click NE Login.Then, the IE displays the
NE Login dialog box.

• Step 5:Enter the User Name and the Password. Then, click OK.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 34
Web LCT Configuration – Modifying the NE ID

Step 1 In the NE Explorer, choose Configuration > NE Attribute from the


Function Tree. Click Modify NE ID.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 35
Web LCT Configuration – Modifying the NE ID

Step 2 Enter a new ID and click OK.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 36
Web LCT Configuration – Modifying the NE ID

Step 3 In the NE list, delete the original NE. Create a new NE with the new ID.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 37
Web LCT Configuration – Configuring IF Protection

 The supported IF protection is 1+1 HSB, 1+1 SD, and 1+1 FD.
Create IF protection

Step 1 In the NE Explorer, choose Configuration > IF 1+1 Protection from the
Function Tree.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 38
Web LCT Configuration – Configuring IF Protection

Step 2 Click New and enter the information of the IF protection. Click OK or
Apply.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 39
Web LCT Configuration – Configuring IF Protection

 Perform IF protection external switching. The priorities of external switching


commands are as follows: clear, lockout, force, and manual.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 40
Web LCT Configuration – Setting IF Attributes
 You can set the following IF attributes by using the T2000 Web LCT: working mode,
link ID, IF port loopback, 2 Mbit/s wayside service, and ATPC-related information.
 In the NE Explorer, select an IF board and choose IF Interface from the Function
Tree.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 41
Web LCT Configuration – Setting IF Attributes

• You can enable automatic transmit power control (ATPC), and adjust the
threshold and the ATPC adjustment.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 42
Web LCT Configuration – Setting RF Attributes
 By using the T2000 Web LCT, you can query and configure the following RF
attributes: transmit frequency, T/R spacing, transmitted power, ODU
manufacturer information, RF loopback status, and ODU status.
 Frequency attributes

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 43
Web LCT Configuration – Setting RF Attributes

Power attributes

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 44
Web LCT Configuration – Setting RF Attributes

ODU manufacturer information

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 45
Web LCT Configuration – Setting RF Attributes
In the Advanced Attributes tab, you set RF loopback and ODU status.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 46
Web LCT Configuration – Configuring a Service

 This operation is applicable to VC4, VC3, and VC12 services.

 Procedure

Step 1 In the NE Explorer, Configuration -> Cross-Connection


Configuration from the Function Tree.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 47
Web LCT Configuration – Configuring a Service

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 48
Web LCT Configuration – Configuring a Service

Step 2 Click New, enter the information of a service and click OK or Apply.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 49
Web LCT Configuration – Configuring an SNCP Service
 This operation is applicable to VC12, VC3, and VC4 SNCP services.

 Procedure

Step 1 In the Cross-Connection Configuration window, click Create SNCP. Enter the
information of an SNCP service.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 50
Web LCT Configuration – Configuring an SNCP Service
Step 2 After you create an SNCP service, the window is divided into two panes.
The upper pane displays the working service and the lower pane displays the
protection service. You can perform external switching for the working and
protection services.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 51
Web LCT Configuration – Converting a Service
 The T2000 Web LCT supports the conversion between a normal service and an
SNCP service.
 To convert a normal service to an SNCP service, select a normal service,
right-click and choose Convert to SNCP from the shortcut menu. Enter the
source of the service in the protection channel and click OK.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 52
Web LCT Configuration – Converting a Service
 You can convert the working or protection channel of an SNCP service to a normal
service.
 To convert a working channel, right-click the service in the working channel and
choose SNCP Working Service Change to Normal Service from the shortcut menu.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 53
Web LCT Configuration – Converting a Service

 To convert a protection channel, right-click the service in the protection channel and
choose SNCP Protection Service Change to Normal Service from the shortcut menu.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 54
Web LCT Configuration – Alarm
 By using the T2000 Web LCT, you can view the current and history alarms, the
reporting status of alarms for an NE and boards, and abnormal events.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 55
Web LCT Configuration – Performance
The T2000 Web LCT supports 15-minute and 24-hour performance monitoring
intervals.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 56
Web LCT Configuration – Performance
 You can view the current and history performance data, UAT events, threshold
crossings, and performance monitoring status. You can set the performance
threshold and reset a board registry.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 57
Web LCT Configuration – Communications

 The RTN 600 uses the OSP NE platform.


 You can set multiple protocol stacks, including the OSI, IP, and HWECC.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 58
Web LCT Configuration – Communications
 For DCC management, an IF board supports the configuration of different DCC
rates in different working modes.
 When the working mode is PDH, the configuration of one-byte DCC (D1-
D1) rate is supported.
 When the working mode is SDH, the configuration of D1-D3, D4-D12, D1-
D12, and D1-D1 is supported.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 59
Contents

1. Introduction to Management Systems

2. Introduction to T2000 Web LCT

3. Introduction to T2000

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 60
Contents

 Introduction to T2000
 3.1 Main Characteristics
 3.2 Application Scenario
 3.3 Configuration Operations

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 61
T2000 Main Characteristics
 The T2000 consists of server and client.
 The server is developed based on C++ and the client is based on
Java.
 The T2000 manages a maximum of 1000 equivalent NEs and
supports concurrent operations of 32 clients.
T2000 server
T2000 client T2000 client

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 62
T2000 Main Characteristics
 Modular architecture
 Open and integrated
 High efficiency and reliability

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 63
Contents
 Introduction to T2000
 3.1 Main Characteristics
 3.2 Application Scenario
 3.3 Configuration Operations

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 64
T2000 Application Scenario

 Subnet management system (SNMS)


 Applicable to small and medium network management
 Provides power NE management functions
 Uniformly manage the RTN/SDH/ASON/MSTP/WDM
equipment
 Provides the standard northbound interfaces and supports OSS
integration

iManager T2000

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 65
Contents
 Introduction to T2000
 3.1 Main Characteristics
 3.2 Application Scenario
 3.3 Configuration Operations

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 66
Contents
 Configuration Operations
 3.3.1 Microwave link
 3.3.2 Alarm
 3.3.3 Performance
 3.3. 4 Linear MSP

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 67
T2000 Configuration – Creating a Microwave Link
 The T2000 allows you to create a Microwave link. You can view the
networking on the Main Topology.
Step 1 On the Main Topology, right-click and choose Microwave link from
the shortcut menu. Enter the information of the Microwave link.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 68
T2000 Configuration – Creating a Microwave Link
 Alternatively, click the icon on the toolbar to display the Create Link window.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 69
T2000 Configuration – Creating a Microwave Link

Step 2 Click OK or Apply. The link is displayed as follows:

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 70
T2000 Configuration –Creating a Microwave Link

 When the source and the sink have different working modes, the
link status is abnormal.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 71
Current Alarm Statistics

 An NE reports current alarms to the T2000.


 You can filter alarms according to the report time of alarms.
 You can view alarm statistics in each NE.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 72
Customizing Alarm Attributes
 You can customize alarm functions, such as alarm severity, alarm
suppression, and alarm reporting.
 The T2000 supports a maximum of 16 alarm templates.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 73
Alarm Correlation Analysis and Suppression

A number of NE alarms Alarm analysis rule


Root alarm

Characteristics:
 Retain the root alarms.
 Suppress the non-root alarms.
 Customize the analysis rules.
Suppress non-
root alarms

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 74
Customizing Performance Threshold
 The T2000 supports customization of a maximum of 16
performance thresholds.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 75
History Performance Analysis

 The T2000 provides graphic history performance data analysis.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 76
T2000 Configuration

 The T2000 and T2000 Web LCT are the same in terms of service configuration,
IF protection, IF and RF attributes, and communications. Refer to the description
in the T2000 Web LCT part.

Copyright © 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 77