You are on page 1of 34

T775 Series 2000 Stand-Alone Controller

New Product Introduction Sales Presentation February 5, 2007

T775 Series 2000


T775 Series 2000 replaces

- T775 Series 1000 models - H775 Humidity Controllers


Release date set for second quarter 38 existing models replaced by 14 new T775 models

T775 Series 2000

Informative Home Display

Relay Status Sensor Temperature Modulating Output Status Digital Input Status

Easy to Use Keypad

Home Screens Provide Useful Info


See sensor, modulating output, and relay configuration information See senor, modulating output, and relay status information Use the left and right arrow buttons to scroll through status screens for all defined outputs, modulating, and relays

Easy-to-Use Graphical Interface


Menu driven programming As easy to use as your cell phone Program with clear, plain language prompts

Easy programming saves installation time


5

Time Clock Scheduler Built-In


For Setback or Disable Output Option Save energy during unoccupied times Gives you more control over your equipment without needing to purchase an additional time clock All T775 models include the scheduler

Energy saving feature


6

Up to 2 Independent Modulating Outputs


Configure each output individually for

- 0-10 Vdc, - 2-10 Vdc, - 4-20 mA, or - Series 90


Versatility saves time in selecting the right control for the job

One model handles many field requirements


7

NEMA 4x Enclosure Option


Protected from water and corrosion Install in animal confinement areas, washdown areas, swimming pools, and similar locations Fours models with NEMA 4x enclosures; all others have NEMA 1

- T775B2016 - T775B2024 - T775M2022 - T775M2014

The right control for harsh locations


8

Modulating High or Low Limit Control


Equipment protection If you need to protect a coil from freezing, or your equipment from overheating Gives you the ability to adjust your control temperature at sensor A to protect equipment at sensor B Three models offer hi/low limit control feature:

- T775R2043 - T775M2048 - T775M2030

Consistent control while protecting your equipment


9

Extended Temperature Range


Setpoint temperature range of -40F to 248F Gives you the ability to control a wider range of temperatures with a single device One device covers it all

10

Configure Integral and Derivative Times


For applications where pinpoint control is required Option is standard on every device PI control on modulating outputs is setup by default to behave just like the previous T775 Series 1000, but now you can adjust reaction times and behavior as you like it, giving you more control.

11

Digital Input Option


Connect an external time clock or any external switch to the digital input Allows you to either disable all outputs or trigger them for a programmed setback temperature Standard on all models

12

Reset Models with Simplified Setup


Vastly simplified reset programming Simply enter the high and low control temperatures and the corresponding high and low outdoor temperatures Reset saves energy - as the outside temp gets colder you can reset the setpoint temperature to save energy

Faster setup & energy savings for customers


13

Reset Set-Up

14

Power Supply
All T775s can be powered with low or line voltage

- 24 Vac - 120/240 Vac


No need to add a separate transformer

No guessing which control youll need


15

Configure Minimum Off Time


Protect equipment by setting a minimum off time if needed Reduces the need for a separate time delay device to protect equipment Set once for all relays Option available on all models with relay outputs.

Set once for all relays


16

Sensor Calibration
Calibrate input sensors +/-10F

- T775U calibrations values are


+/-10% of the user defined input range

Use to compensate for resistance drops in wire leads Use to offset the input temperature for sensor location or for any other reason

Flexible and accurate control


17

Name Each Sensor


Select from a list of descriptive labels for each sensor Label will always include A, B, and C designators for Sensor A, Sensor B, and Sensor C Sensor labels displayed on the Home screen

18

Sensor Names Appear on Home Screen

Sensor Names Always Displayed on the Home Screen

19

Display Relay Runtime


Quickly and easily check to see how many hours a stage has been running Reset to zero at any time Available on all models

Runtime Displayed for Each Relay

20

Locking Keypad
Keep configuration secure from unauthorized changes Easy to lock/unlock but not obvious how to unlock unless you know the system

Lock Icon Indicates Keypad is Locked

21

Fewer Models
14 Series 2000 T775 models replace 38 Series 1000 T775 models Reduce inventory Eliminate the headache of choosing the right controller

Reduced inventory keeps the money in your pocket


22

Standard Models
Use in standard applications Minimal setup and configuration required All models ship with one temperature sensor; all except single relay model can accept two sensor inputs. Floating output option now available!
Analog Outputs 4-20mA, 0-10Vdc, 2-10Vdc, & Series 90 1 1 2 2

Product Number T775A2009 T775B2016 T775B2032 T775B2024 T775B2040

Description Standard Standard-NEMA 4X Standard Standard-NEMA 4X Standard

Replaces T775A1001/U T775A1019/U T775B1000/U T775C1009/U T775D1008/U T775A1027/U T775A1035/U T775B1018/U T775B1026/U T775B1042/B T775B1042/U

Relay Outputs 1 SPDT 2 SPDT 2 SPDT 4 SPDT 4 SPDT

Floating Output*

Sensor Inputs 1 2 2 2 2

# Sensors Included 1 1 1 1 1

* One floating output eliminates the two relay outputs.

23

Modulating Models
Use in modulating applications, with the option for relay outputs as well. Easily define analog output configuration through programming All models ship with one temperature sensor
Product Number T775M2006 T775M2022 T775M2048 Description Modulating Modulating-NEMA 4X Modulating Replaces T775E1015/U T775E1023/U T775E1056/U T775E1064/U T775E1098/U T775G1005/U T775G1013/U T775G1021/U T775G1039/B T775E1114/U T775F1022/U T775F1055/U T775F1089/U Relay Outputs None 2 SPDT 2 SPDT Analog Outputs 4-20mA, 0-10Vdc, 2-10Vdc, & Series 90 2 2 2 Floatin g Output* Sensor Inputs 2 2 2 # Sensors Included 1 1 1

T775M2014

Modulating-NEMA 4X

4 SPDT

T775M2030

Modulating

4 SPDT

* One floating output eliminates the two relay outputs.

24

Reset Models
Use in applications requiring reset All models ship with two temperature sensors
Product Number T775R2035 T775R2043 Relay Outputs 2 SPDT None Analog Outputs 4-20mA, 0-10Vdc, 2-10Vdc, & Series 90 2 Floating Output* 1 Sensor Inputs 2 2 # Sensors Included 2 2

Description Reset option Reset option

Replaces T775J1001/U T775J1076/U T775J1019/U T775J1027/U T775J1035/U T775J1043/U T775J1050/U T775J1068/U

T775R2027

Reset option

2 SPDT

T775R2001 T775R2019

Reset option Reset option

4 SPDT 4 SPDT

2 2

2 2

* One floating output eliminates the two relay outputs.

25

Boiler with Reset Model


Handle multi-stage boiler applications with this single controller. 1 dedicated pump output Staging for up to 12 relays 1 digital output alarm Pump exercise, pump pre-purge and post-purge, warm weather shut-down. Displayed run time Ships with three temperature sensors
Analog Outputs 4-20mA, 0-10Vdc, 210Vdc, & Series 90 Sensor Inputs Available 3

Product Number

Description

Replaces

Relay Outputs

# Sensors Included

Output Reset

T775P2003 T775S2008

Special Boiler with Reset Four relay expansion module add one or two for a total of 8 or 12 relays.

4 SPDT 4 SPDT

26

Stage Sequencer with Reset Model


Four stages or add up to two optional 4-stage expansion relay modules for 8, or 12 stage operation Flexible setup allows you to configure these stages any way you like for heating, cooling or divide up the stages as you like for both heating and cooling Operating up to 12 stages, these can control multiple low-mass boilers, chillers, and/or electric heat from a single control Expandable to 12 relays with the T775s 4-Relay Expansion Module Ships with one temperature sensor
Analog Outputs 4-20mA, 0-10Vdc, 2-10Vdc, & Series 90 Sensor Inputs Available 2

Product Number

Description

Replaces

Relay Outputs

# Sensors Included

Output Reset

T775L2007 T775S2008

Stage Sequencer with Reset Option Four relay expansion module add one or two for a total of 8 or 12 relays.

4 SPDT 4 SPDT

27

Universal Model for pressure, humidity, etc.


Easy setup for configuring control of pressure, humidity, temperature, or any medium with a 0-10Vdc or 4-20mA sensor input. Select from a variety of pressure, humidity, etc. sensors for the desired application. Control humidity with % RH displayed, or control pressure with in. w.c., psi, Pa, or kPa displayed. Outputs include 2 modulating and two relay outputs that can each have its own setpoint. Ability to reset the output based on outdoor temperature, handy when you need to reduce window condensation when setting humidity levels Complete versatility in a single control allows you the freedom to do what the job requires
Product Number Relay Outputs Analog Outputs 4-20mA, 0-10Vdc, 2-10Vdc, & Series 90 2 Sensor Inputs Availab le 2 # Sensors Included Output Reset

Description

Replaces

T775U2006

Universal - Humidity, Pressure, etc.

H775A1006/U H775A1022/U H775A1048/U H775A1063/U H775B1005/U H775C1004/U H775D1003/U H775E1002/U

2 SPDT

28

T775 Legacy Product Comparison


Feature/Function
Relays Relay Contact Rating Power Supply Modulating Output Scheduler

T775 Series 1000


1 to 4 SPDT 9.8A full load at 120Vac 24, 120, 240 VAC 1 modulating, up to 3 SPDT relays No

T775 Series 2000


1 to 12 SPDT (with T775S) Same Same 2 modulating, up to 4 SPDT relays. Standard on all models. Provides one setback period per day, configurable for each day of the week. PT1000 IEC 751 Same Same UL, CE, C-Tick same Models with mod output support all types (except floating option which is offered on the relay output models). Yes Yes -40 to 248F 1 to 150F Configurable (settable integral time)

Temp Sensor Watertight Temp Sensor NEMA 4X enclosure Approvals Ambient temp range Modulating outputs: 0 - 10 Vdc, 2 - 10 Vdc, 4 20 mA, Series 90 Floating Supports 0 - 10 Vdc output Supports floating output Temperature Setpoint Range Differential/Throttling range Integral Action

PT3000 With NEMA 4X models Optional up to 4 relays UL -40 to 140F Requires a separate model for each type supported No No -40 to 220F 1 to 35F Fixed

29

T775 Legacy Product Comparison (cont)


Feature/Function
Digital Input

T775 Series 1000


Disable all outputs

T775 Series 2000


Options: 1) Disable all inputs 2) Alternate setpoints for all outputs Yes - with simplified configuration Configurable for each output LCD user interface Optional Same F, C, in wc, psi, %, kPa, Pa Configurable Minimum off activated at powerup (yes/no choice for each relay) Yes Yes single setpoint drives multiple relays. Yes Universal Model supports relay or modulating RH control, with Temp Reset option Yes- single setpoint drives multiple relays, Alarm Output, 3 sensor inputs available (supply, return, outside).

Reset Reset optional Reset Set up Irreversible setpoint high limit to meet some codes Engineering Units Standard Models Engineering Units Universal Model Relay Minimum Off Time Power up action Sensor Calibration Output Sequencing Option High or Low Modulating Limit Control Humidity Control

Yes All outputs or none. DIP switches No F or C NA No 300 second countdown before control enabled No No No H775 up to 4 relays, 2 sensors required for mod out No

Boiler Special Model

30

Johnson ControlsA350
Strengths
Modular design Easy to install Simple to use Low cost , simple single relay model (a large share of the business) Customer loyalty

Challenges
Multiple parts to buy for each installation Cost goes up quickly when modules are added Expensive when using multiple relays with an LCD display Feature set cant compare with T775, see next slide

31

Competitive ComparisonJohnson Controls


Feature
Timeclock with setback Modulating Outputs Built-in Display High/Low Mod Limit Control Wide Setpoint Range

Honeywell
7 day, 2 events per day 0-10 Vdc, 4-20 Vdc, 4-20 mA, Series 90 & Floating Yes Yes -40F to 248F All models, with Celsius too. 1-150F Yes Yes Yes Yes Yes Yes

Johnson Controls
no 0-10 Vdc and 4-20 mA No No Either -30F to 130F or 90F to 250F 2-30F No No No No No No

Throttling Adjustment Range Digital input for setback or disable Sensor Calibration Adjustable minimum off time Integral voltage options Nema 4x Models Irreversible high setpoint limit

32

Tekmar264 and others


Strengths
Wide Range of products Application knowledge Excellent Web site Support consulting engineers

Challenges
Can be complicated to set up Fixed segment display cryptic to decipher without instructions High cost products

33

www.honeywell.com

34

You might also like