Course Objectives
Know about packet transport system and its structure Grasp functions, working principles and applications of ZXCTN 9008 cards Know networking application and configuration of ZXCTN 9008 devices

Course Outline ZTE PTN Products Family


ZXCTN 9008 Overview Hardware Structure Software Structure System Functions Boards Networking Application and Configuration

ZTE PTN Products Family

Internal Use Only

Course Outline
ZTE PTN Products Family

ZXCTN 9008 Overview


Hardware Structure Software Structure System Functions Boards Networking Application and Configuration

ZXCTN 9008 Overview

Internal Use Only

ZXCTN 9008 Overview

Internal Use Only

Features of ZXCTN 9008 Multi-Service Unified Carrier Platform, Meeting Development of Full Services Advanced Timing Processing Capability, Meeting Accurate Synchronization Demand Perfect Point-to-Point QoS Solution, Providing Refined Differential Services Powerful Hierarchical OAM Function, Improving Network Availability Multi-Protection Mechanism, Ensuring Network Security Sound Compatibility, Supporting High-Speed Development of Service Network Unified NM System, Simplifying Operation and Maintenance Intelligent Power Consumption Regulation, Saving Resources

System Applications

Internal Use Only

ZXCTN 9008 provides access and transmission of packet service and is compatible with access and transmission of Time Division Multiplex (TDM) service. System also provides perfect service protection, OAM and clock synchronization and has carrier-class service transmission characteristics.

Course Outline
ZTE PTN Products Family ZXCTN 9008 Overview

Hardware Structure
Software Structure System Functions Boards Networking Application and Configuration

Cabinet
Cabinet Dimensions:

Internal Use Only

2200mm (H) x 600mm (W) x 600mm (D) Cabinet Weight: 110kg

Subrack

Internal Use Only

1 1 1 1 1 1

1 1 1 1 1

1. LCD 2. Fan Plug-in Box 3. Cabling Trough 4. Service Card Section 5. Main Control Board Section 6. Switch Fabric Card Section 7. Filtering Mesh 8. Air Inlet 9. Power Module 10. Handle

Card Slots on Subrack

Internal Use Only

Fan Plug-in Box

Internal Use Only

1 1

1. Lock Button 2. Security Alarm Sign 3. Indicator 4. Fan

System Components

Internal Use Only

ZXCTN 9008 adopts rack design and hardware architecture of the entire system is composed of backplane, main board, switch fabric card, service card, intelligent platform management sub-system, power module, fan and so on.

Course Outline
ZTE PTN Products Family ZXCTN 9008 Overview Hardware Structure

Software Structure
System Functions Boards Networking Application and Configuration

NM Software

Internal Use Only

Manager GUI Database

System Software Structure

Internal Use Only

System Software Structure

Internal Use Only

Structure of Main Control Software

System Software Structure

Internal Use Only

Card Software Structure

Internal Use Communication Protocols and Interfaces Only

Interface Name MCC Interface

Description This is management communication channel interface, used for communication between NE's and conforming to TCP/IP protocol. This is system basic configuration interface, used for initialization configuration, daily maintenance and fault handling. The interface conforms to RS232 asynchronous serial interface protocol. This is an assistant management interface, supporting to implement remote network management through Modem. This is a 10/100 Mbps Ethernet NM interface.

CON Interface

AUX Interface

MGT Interface

Course Outline
ZTE PTN Products Family ZXCTN 9008 Overview Hardware Structure Software Structure

System Functions
Board Networking Application and Configuration

Services and Functions

Internal Use Only

Service Processing Model

Services and Functions

Internal Use Only

Service Types
Signal Format/Applicable Standard

Service Types Ethernet Services

E-LINE Service IEEE 802.3 and MEF MEF2/MEF4 E-LAN Service E-TREE Service

ATM Service ATM STM-1 TDM Service TDM STM-1

RFC4717, RFC4816, AF-PHY-0086.001 and CES ITU-T I.363 , B-ISDN, AAL1 standard, AF-VTOA-0078 and CES.

Services and Functions

Internal Use Only

Service Processing Capability


Switching Capacity
Attribute Backplane Bandwidth Switch Capacity packet forwarding rate Description 2.52 Tbps 1.6 Tbps 476 Mbps

Services and Functions

Internal Use Only

Service Processing Capability


Access Capacity
Interface Type Max. Card Accesses 4 48 48 48 48 Max. Device Accesses 32 384 384 384 384 Service (Payload) Type IP IP IP IP IP

Interface

Ethernet

10GE (Optical) GE (Optical) GE (Electrical) FE (Optical) FE (Electrical)

Services and Functions

Internal Use Only

Service Processing Capability


Access Capacity
Interface Type Max. Card Accesses 8 16 2 8 16 16 16 Max. Device Accesses 64 128 16 64 128 128 128 Service (Payload) Type TDM TDM IP IP IP IP ATM

Interface

STM-N

STM-4 STM-1 POS STM-64 POS STM-16 POS STM-4 POS STM-1 ATM STM-1

Board Naming List


Board Code P9008-MSC P9008-SC P90S1-24GE-SFP P90S1-24GE-RJ P90S1-48GE-SFP P90S1-48GE-RJ P90S1-24GE2XGE -SFPXFP Board Name

Internal Use Only

Management & Switching Card for 9008 Switching Card for 9008 24-port Gigabit Ethernet SFP Interface Line Card (supporting SyncE) 24port Gigabit Ethernet RJ45 Interface Line Card (supporting SyncE) 48-port Gigabit Ethernet SFP Interface Line Card (supporting SyncE) 48-port Gigabit Ethernet RJ45 Interface Line Card (supporting SyncE) 24-port Gigabit Ethernet SFP Interface and 2-port 10Giga Ethernet XFP Interface Line Card (supporting SyncE)

Board Naming List


Board Code P90S1-2XGE-XFP P90S1-4XGE-XFP P90S1-LPCA P90-1P192-XFP P90-8P12/3-SFP PM-DC2UA PM-AC2U M9008FAN Board Name

Internal Use Only

2-port 10Gigabit Ethernet XFP Interface Line Card (supporting SyncE) 4-port 10Gigabit Ethernet XFP Interface Line Card (supporting SyncE) Multi-service Mother Board with 2 sub Card slot) 1-port OC-192c XFP Interface POS Sub Card 8-port OC-12c/OC-3c configurable SFP Interface POS Sub Card Power DC board for 9008 Power AC board for 9008 Fan board for 9008

Board Slot List


Number of Slot ID Occupied Slots Main Control Board P9008-MSC 1 9# and 10# Board Type Board

Internal Use Only

Remarks Main control unit supports 1:1 redundancy. The redundancy

Switch Fabric Card P9008-SC

configuration is recommended. 11# and 12# 2 switch fabric cards and 2 switching modules on main control board together compose 4 switching plane and provide 3+1 load balancing and redundancy protection. 13#~15# 13#~15# Supporting 1 2 redundancy. The redundancy configuration is recommended. Supporting 1 1 redundancy. The redundancy configuration is recommended. -

Power Module

PM-AC2U PM-DC2UA

1 1

Fan Module

M9008-FAN

16#~17#

Board Slot List


Board Type Service Processing Card Board P90S1-24GE-SFP P90S1-24GE-RJ P90S1-48GE-SFP P90S1-48GE-RJ P90S1-24GE2XGESFPXFP P90S1-2XGE-XFP P90S1-4XGE-XFP Multi-Service P90S1-LPCA Mother Board Interface Sub- P90-1P192-XFP Card P90-8P12/3-SFP 1 1 1 1 1 1 1 1 Number of Occupied Slots Slot ID 1# ~ 8# 1# ~ 8# 1# ~ 8# 1# ~ 8# 1# ~ 8# 1# ~ 8# 1# ~ 8# 1# ~ 8#

Internal Use Only


Remarks Working together with interface subcard. Working together with multi-service mother board. Subcard itself does not occupy slot.

P90S1-LPCA P90S1-LPCA

P9008-MSC

Internal Use Only

Front Panel of SMB Board

1. Fixed Screw 2. Debugging Port CONSOLE 3. Ethernet Management Interface MANAGEMENT 4. AUX Management Interface 5. Board Reset Button RST 6. Board Master/Slave Switchover Button EXCH 7. Board Copy Button CPY 8. SD Card Read-Write Indicator ACT 9. SD Card Interface 10. USB Interface 11. Board Master Status Indicator MST 12. Board Slave Status Indicator SLA 13. Running Status Indicator of Power Module PWR1~3 14. Running Status Indicator of Switch Fabric Card SFC1~2 15. Running Status Indicator of Service Card LIC1~8 16. Lever

1 1 111 1

11 11 1 1 1 11 1 1

1 1

1 1

P9008-MSC

Internal Use Only

Indicator Status
Indicator Status MST ACT (Green) ALM (Red) RUN (Green) SLV ALM (Red) RUN (Green)

Board Running Status

Data is being Constantly ON operated on SD card. Board is in master status. Board is in master status with alarm. Board is in slave status. Board is in slave status with alarm. -

Constantly ON-

Constantly ON

Constantly ON Constantly ON-

Constantly ON-

P9008-MSC

Internal Use Only

Indicator Status
PWR1~3 ALM (Red) RUN (Green) Constantly ON Constantly ON Indicator Status SFC1~2 ALM (Red) RUN (Green) LIC1~8 ALM (Red) Constantly ON RUN (Green)

Board Running Status

Power board in corresponding slot is running normally.

Power board in corresponding Constantly slot reports alarm. ON Switch fabric card in corresponding slot is running normally. Switch fabric card in corresponding slot reports alarm. Service card in corresponding slot is running normally. Service card in corresponding slot reports alarm. -

Constantly ON -

Constantly ON

P9008-SC

Internal Use Only

1. Fixed Screw

2. Lever

P90S1-24GE-RJ

Internal Use Only

11

1. Fixed Screw 2. GE Electrical Interface 1~24 3. GE Electrical Interface Working Status Indicator LINK/ACT 4. Lever

P90S1-24GE-SFP

Internal Use Only

11

1. Fixed Screw 2. GE Optical Interface 1~24 3. GE Optical Interface Working Status Indicator LINK/ACT 4. Lever

P90S1-48GE-RJ

Internal Use Only

1. Fixed Screw 2. GE Electrical Interface 1~48 3. GE Electrical Interface Working Status Indicator LINK/ACT 4. Lever

P90S1-48GE-SFP

Internal Use Only

1. Fixed Screw 2. GE Optical Interface 1~48 3. GE Optical Interface Working Status Indicator LINK/ACT 4. Lever

P90S1-2XGE-XFP

Internal Use Only

11 1

1. Fixed Screw 2. Connection Status Indicator LINK 3. Data Read-Write Indicator ACT 4. 10GE Optical Interface 5. Lever

P90S1-4XGE-XFP

Internal Use Only

11 1

1. Fixed Screw 2. Connection Status Indicator LINK 3. Data Read-Write Indicator ACT 4. 10GE Optical Interface 5. Lever

P90S1-24GE2XGE-SFPXFP

Internal Use Only

11

11 1

1. Fixed Screw 2. GE Optical Interface Working Status Indicator LINK/ACT 3. GE Optical Interface 1~24 4. GE Optical Interface Connection Status Indicator LINK 5. 10GEOptical Interface Data Read-Write Indicator ACT 6. 10GE Optical Interface 1~2 7. Lever

P90-1P192-XFP

Internal Use Only

11

1. POS Interface Connection Status Indicator LINK 2. POS Interface Data Transmission and Reception Indicator ACT 3. 10GE POS Interface

P90-8P12/3-SFP

Internal Use Only

1 1

1. 155M/622M POS Interface 1~8 2. POS Interface Connection Status Indicator LINK 3. POS Interface Data Transmission and Reception Indicator ACT

PM-DC2UA

Internal Use Only

1 1

1. Fixed Screw 2. Power Switch 3. -48 V Terminal 4. -48 V RTN Terminal 5. Plug-In Box Handle

PM-AC2U

Internal Use Only

1. Fixed Screw 2. 100~240 V AC Input 3. Power Switch 4. Plug-In Box Handle