You are on page 1of 41

Core Network Planning Workshop

DX200 Platform

Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Contents
Nokia MSCi, TMSCi, HLRi and SRRi (DX 200 platform) HW overview (cabinets, cartridges, functional units, PIU, MB etc) Interfaces Capacities and roadmap Nokia MSCi Nokia Transit MSCi Nokia Compact MSCi Nokia HLR

For internal use 2 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Cartridge Construction Products - i-series

DX 200 MSCi DX 200 Transit MSCi DX 200 Compact MSCi DX 200 HLRi

For internal use 3 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Network Structure
NMS
SMSC VMS

PBX
MSCi

P S T N / I S D N

BSS
Transit MSCi

IN
HLRi

SMSC

VMS PBX

NETWORK SUBSYSTEM
For internal use 4 Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007

Compact MSCi

Cabinets
Height: 2 m, width: 90 cm, depth: 60 cm, according to ETSI standard Internal cabling is always the same Strappings done with pre-wired connectors All delivered cabinets are pre-wired and equipped with all necessary cartridges and cables Shorter installation time on site Considerably fewer parts to be mounted

For internal use 5 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Cabinet Types
MOMC - Main Operation and Maintenance Cabinet for MSCi VLRC - Visitor Location Register Cabinet for MSCi ETC - Exchange Terminal Cabinet for MSCi GSWC - Group Switch Cabinet for MSCi IWC - InterWorking Cabinet for MSCi GSC - General Signalling Cabinet for Transit MSCi MMAC - Compact MSCi Cabinet A MMBC - Compact MSCi Cabinet B HLRC - Home Location Register Cabinet HLGC - Home Location Group Switch Cabinet

For internal use 6 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Cabinet Parts
COVER FOR POWER SUPPLY SIDE COVER PLATE - SCP OR EMC GASKET FRAME POWER SUPPLY CONNECTOR GROUP FILTER

FUSE UNIT (PDFU)

CARTRIDGE

DOOR RIGHT

DOOR LEFT

RAIL FOR SHELVES

CABLE SUPPORT

CARTRIDGE SHELF

HORIZONTAL GROUNDING BAR

VERTICAL GROUNDING BAR

ADJUSTABLE FEET

WHEEL

COVER FOR WHEEL BOX

For internal use 7 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Cartridges

M4 x 10

For internal use 8 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

DX 200 MSCi Capacity (M13)


1,000,000 subscribers 200,000 Tel. subs 1,000,000 BHCA 1,500,000 BHSM 16,700 Erlangs 1392 ext. PCMs 416 C7 links

Extendable from 100,000 subscribers (7 cabinets + 4 cabling cabinets)


to 1,000,000 subscribers (15 cabinets + 8 cabling cabinets) BHCA capacity from 100.000 to 1,000,000 1,500,000 SMS/BH 688 PCMs with ECU 2048 GSW

For internal use 9 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

DX 200 MSCi
BSS
ET TGFP ECET CLS

PSTN

CDSU

GSW ECET ET

PABX NSS

CCSU

MFSU

BSU

PAU MB

CASU

BDCU

X.25 or LAN to OMC and SMS

CCMU

CMU

CM

VLRU
LAN

STU
LAN

CHU

OMU
LAN

VDU and LPT VDU and LPT

For internal use 10 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

MSCi - Functional unit configurations


max CCSU CASU PAU BSU VLRU pairs ET ET&ECU BDCU CHU pairs CDSU MFSU
For internal use 11 Nokia Siemens Networks

14 (incl. spares) 15 + 1 8 704 688 3 3 42 5+1

DX200 Platform.ppt / ET / 08-2007

MSCi Cabinet Layout (max. configuration)- Row 1


MOMC
PDFU PDFU 0 1 CCMU 1 2 3 CMU 0 M 0 M 1 4 5 CM 0 CM 1 SD SD OMU OMU 6 7 CMU 1 OMU 0 OMU 1 8 9 MFSU 0 MFSU 1 BDCU 0 10 xSU 0 xSU 1 xSU 2 xSU 3 xSU 4 xSU 5 xSU 7 xSU 8 xSU 9 xSU 11 xSU 12 xSU 13 BSU 0 BSU 1 BSU 2 BSU 3 BSU 4 BSU 5 BSU 6 BSU 7 BSU 8 BSU 9 BSU 10 BSU 11 BSU 12 BSU 13 BSU 14 BSU 15 STU 0 SD STU SD STU STU 1 CHU 0-0 SD CHU SD CHU CHU 0-1 CHU 1-0 SD CHU SD CHU CHU 1-1 CHU 2-0 SD CHU SD CHU CHU 2-1 VLRU VLRU VLRU VLRU 0-0 0-1 1-0 1-1 VLRU VLRU VLRU VLRU 2-0 2-1 3-0 3-1 VLRU 4-0 VLRU 4-1 VLRU 5-0 VLRU 5-1 VLRU 6-0 VLRU 6-1 VLRU 7-0 VLRU 7-1 BDCU 1 PDFU

VLRC
PDFU PDFU

VLRC
PDFU PDFU

VLRC
PDFU PDFU

VLRC
PDFU CLBU

CLBU

CLBU

CLBU

CLBU

CCMU 0

MFSU 2

BDCU 2

MFSU 3

GSU 6

CLBU

CLBU

CLSU

MFSU 4

GSU 10

CLBU

MFSU 5

NOTE: xSU = CCSU/CASU/PAU as needed

For internal use 12 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

MSCi Cabinet Layout (max. configuration) - Row 2

GSWC
PDFU GSW 0-0 GSW 0-1 PDFU
0 1 2 3 4 5 6

GSWC
PDFU GSW 1-0 GSW 1-1 PDFU
0 1 2 3

ETC
PDFU CLBU PDFU ECET
2 3 0 1 PDFU

IWC
PDFU CLBU

ETC
PDFU CLBU PDFU ECET
2 3 0 1

CDSU CDSU

ECET
4 5 6

ECET
4 5

CDSU CDSU CDSU

ECET

ECET
4 5

CDSU CDSU CDSU 6 6

GSW 0-2 GSW 0-3

7 8 9 10

GSW 1-2 GSW 1-3

ECET
8 9

ECET EC

7 CDSU CDSU CDSU 8 9

ECET

ECET EC

7 8 9

EC
10

EC
10

CDSU CDSU CDSU

EC

EC
10

For internal use 13 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

MSCi Cabinet Layout (max. configuration) - Row 3

ETC
PDFU CLBU PDFU ECET
2 3 0 1 CDSU PDFU

IWC
PDFU CLBU

ETC
PDFU CLBU PDFU ECET
2 3 0 1 CDSU PDFU

IWC
PDFU CLBU

ETC
PDFU CLBU PDFU ECET
2 3 0 1

CDSU

CDSU

ECET

ECET
4 5

CDSU

CDSU CDSU

ECET

ECET
4 5

CDSU

CDSU

CDSU

ECET

ECET
4 5

CDSU 6

CDSU CDSU 6

CDSU

CDSU

CDSU 6

ECET

ECET EC

7 CDSU 8 9 CDSU CDSU

ECET

ECET EC

7 CDSU 8 9 CDSU CDSU

ECET

ECET EC

7 8 9

EC

EC
10

CDSU

CDSU CDSU

EC

EC
10

CDSU

CDSU

CDSU

EC

EC
10

For internal use 14 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

DX 200 Transit MSCi (M13) Capacity

1.400.000 BHCA 20.000 Erlangs 1024 C7 links 1648 ext. PCMs 784 PCMs with ECU

Extendable from 600,000 BHCA to 1,400,000 BHCA

2048 GSW
For internal use 15 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

DX 200 Transit MSCi


MSC
ET TGFP ECET

PSTN

CLS

GSW ECET ET

PABX NSS

MFSU

CCSU

CASU

PAU MB

BDCU

X.25 or LAN to OMC and SMS

CCMU

CMU

CM
LAN

STU
LAN

CHU

OMU

VDU and LPT VDU and LPT

For internal use 16 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Transit MSCi - Functional unit configurations

max CCSU CASU PAU ET ET&ECU BDCU CHU pairs MFSU 33 (incl. spares) 864 784 5 3 4+1

For internal use 17 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Transit MSCi Cabinet Layout (max. configuration) row 1


MOMC
PDFU PDFU 0 1 CCMU 1 2 3 CMU 0 M 0 M 1 4 5 CM 0 SD OMU SD OMU CM 1 6 7 CMU 1 OMU 0 OMU 1 8 9 MFSU 0 MFSU 1 BDCU 0 10 xSU 6 xSU 7 xSU 8 xSU 15 xSU 16 xSU 17 xSU 24 xSU 25 xSU 26 xSU 3 xSU 4 xSU 5 xSU 12 xSU 13 xSU 14 xSU 21 xSU 22 xSU 23 xSU 30 xSU 31 xSU 32 STU 0 SD STU SD STU STU 1 CHU 0-0 SD CHU SD CHU CHU 0-1 CHU 1-0 SD CHU SD CHU CHU 1-1 CHU 2-0 SD CHU SD CHU CHU 2-1 xSU 0 xSU 1 xSU 2 xSU 9 xSU 10 xSU 11 xSU 18 xSU 21 xSU 20 xSU 27 xSU 28 xSU 29 PDFU BDCU 1

GSC
PDFU PDFU

GSC
PDFU PDFU

GSC
PDFU PDFU

GSC
PDFU

CLBU

CLBU

CLBU

CLBU

CLBU

CCMU 0

MFSU 2

BDCU 2

CLBU

MFSU 3

BDCU 3

MFSU 4

BDCU 4

NOTE: xSU = CCSU/CASU/PAU as needed

For internal use 18 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

CLBU

CLBU

CLSU

Transit MSCi Cabinet Layout (max. configuration) row 2


GSWC
PDFU GSW
2 3

GSWC
0 1

ETC
0 1

ETC
PDFU
0 1

PDFU

PDFU GSW

PDFU

PDFU CLBU

PDFU CLBU

PDFU ECET

0 1 2 3

ECET
2 3

2 3

GSW
4 5 6 7 8 9

GSW
4 5 6 7

ECET

ECET
4 5 6

ECET

ECET
4 5 6

GSW

GSW

ECET
8 9

ECET EC

ECET
8 9

ECET EC

7 8 9

GSW
10

GSW
10

EC

EC
10

EC

EC
10

For internal use 19 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Transit MSCi Cabinet Layout (max. configuration) row 3

ETC
PDFU CLBU PDFU ECET
2 3 0 1

ETC
PDFU CLBU PDFU ECET
2 3 0 1

ETC
PDFU CLBU PDFU ECET
2 3 0 1

ETC
PDFU CLBU PDFU ECET
2 3 0 1

ECET

ECET
4 5 6

ECET

ECET
4 5 6

ECET

ECET
4 5 6

ECET

ECET
4 5 6

ECET

ECET EC

ECET
8 9

ECET EC

ECET
8 9

ECET EC

ECET
8 9

ECET EC

7 8 9

EC

EC
10

EC

EC
10

EC

EC
10

EC

EC
10

For internal use 20 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

DX 200 HLRi (M13)


3,750,000 subscribers 1,250,000 Telemetric Subs
AUC EIR

AuC capacity: 7.500.000 subscribers EIR capacity:


10 million entries on black list
4 million entries on grey list (1...1,000 IMEIs/entry) 200,000 entries on white list (1...1,000,000 IMEIs/entry)

512 C7 links 512 GSW


For internal use 21 Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007

DX 200 HLRi
ET CLS

MSC

GSW ET

HLR

EIRU

CCSU

CMM

BDCU

X.25 or LAN to OMC and SMS

MB
VDU and LPT VDU and LPT

ACU

EMU

HLRU

DBDU
LAN

STU

OMU

For internal use 22 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

HLRi - Functional unit configurations

max CCSU EIRU ACU pairs ET BDCU HLRU pairs 32 + 1 7 5 96 2 10

For internal use 23 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

HLRi (3,750,000 subs) Cabinet Layout

HLGC
PDFU PDFU 0 1 CLSU CMM 0 CMM 1 PDFU

HLRC
PDFU CLBU CLBU PDFU

HLRC
PDFU CLBU CLBU PDFU

HLRC
PDFU CLBU CLBU PDFU

HLRC
PDFU CLBU CLBU PDFU

HLRC
PDFU CLBU CLBU PDFU

HLRC
PDFU CLBU CLBU

CCSU 4

EIRU 0

EIRU 1

EIRU 2

CCSU 13

EIRU 3

CCSU 18

EIRU 4

CCSU 23

EIRU 5

CCSU 28

EIRU 6

ET

ET

ET

ET

ET

2 3

GSW GSW GSW GSW 0-0 0-1 1-0 1-1 4 5 SD SD OMU OMU BDCU 0 6 7 OMU 0 OMU 1 BDCU 1 8 9 CCSU CCSU CCSU CCSU 0 1 2 3 10

DBDU 0-0

SD DBDU

DBDU 0-1

ACU 0-0

SD ACU

ACU 0-1

ACU 1-0

SD ACU

ACU 1-1

ACU 2-0

SD ACU

ACU 2-1

ACU 3-0

SD ACU

ACU 3-1

ET

ACU 4-0

SD ACU

ACU 4-1

STU 0

SD STU

SD STU STU 1

HLRU SD SD HLRU 0-0 HLRU HLRU 0-1

HLRU SD SD HLRU 2-0 HLRU HLRU 2-1

HLRU SD SD HLRU 4-0 HLRU HLRU 4-1

HLRU SD SD HLRU 6-0 HLRU HLRU 6-1

HLRU SD SD HLRU 8-0 HLRU HLRU 8-1

EMU SD SD EMU 0 EMU EMU 1

HLRU SD SD HLRU 1-0 HLRU HLRU 1-1

HLRU SD SD HLRU 3-0 HLRU HLRU 3-1

HLRU SD SD HLRU 5-0 HLRU HLRU 5-1

HLRU SD SD HLRU 7-0 HLRU HLRU 7-1

HLRU SD SD HLRU 9-0 HLRU HLRU 9-1

CCSU CCSU CCSU CCSU 5 6 7 8

CCSU CCSU CCSU CCSU 9 10 11 12

CCSU CCSU CCSU CCSU 14 15 16 17

CCSU CCSU CCSU CCSU 19 20 21 22

CCSU CCSU CCSU CCSU 24 25 25 27

CCSU CCSU CCSU CCSU 29 30 31 32

For internal use 24 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

DX200 SRRi (M12)

56.000.000 single entries


SRR

SRR capacity:
56 million single entries 700.000 number range entries 20.000 queries/sec

47+1 CCSUs 1504 C7 links 192 ET interfaces


For internal use 25 Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007

DX200 SRRi

For internal use 26 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

SRRi (56.000.000 single entries) Cabinet Layout

For internal use 27 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Nokia CS Core Capacity Roadmap


E4 milestones for Major releases and System releases, E5 milestones for Minor releases
M14.2 M14.X M14.0 4Q/07 M14.1 2Q/08 M15.0 1H/09

M13.2 1Q/06

M13.4 3Q/06

M13.6 2Q/07

MSS, MSC, HLR, SRR MGW

M13.0 1Q/05

M13.1 4Q/05

M13.3 2Q/06

M13.5 4Q/06

U4.2 U4.X U3A 1Q/05 U3B 1Q/06 U3C 4Q/06 U4.0 4Q/07 U4.1 2Q/08 U5.0 1H/09

MSC Server System Release 2005


Green E1 milestone reached
For internal use 28 Nokia Siemens Networks

SR2.0 2Q/06

SR2.1 SR2.2 SR2.3 4Q/06 1Q/07 2Q/07

SR3.0 1Q/08

SR3.1 3Q/08

SR4.0 2H/09

2006

2007

2008

2009

DX200 Platform.ppt / ET / 08-2007

Nokia CS Core Capacity Roadmap


M12/U2
MSCi
600.000 subscribers 600.000 BHCA 1.000.000 SMS/BH

M13/U3
MSCi
1.000.000 subscribers 1.000.000 BHCA 1.500.000 SMS/BH

M14/U4
MSCi
1.000.000 subscribers 1.000.000 BHCA 1.500.000 SMS/BH

MSS
600.000 subscribers 600.000 BHCA 1.000.000 SMS/BH

MSS (M13.2)
1.200.000 subscribers 1.200.000 BHCA 1.200.000 SMS/BH

MSS
2.500.000 subscribers 2.500.000 BHCA 2.500.000 SMS/BH

MSS Gateway Mode


1.000.000 BHCA

MSS Gateway Mode


3.000.000 BHCA

MSS Gateway Mode


3.500.000 BHCA

T-MSC
Pure transit 1.2 M BHCA Gateway 1.0 M BHCA

T-MSC
Pure transit 1.4 M BHCA Gateway 1.2 M BHCA

T-MSC
Pure transit 1.4 M BHCA Gateway 1.2 M BHCA

MGW
12.000 simultaneous calls 600.000 BHCA

MGW
15.000 simultaneous calls 900.000 BHCA

MGW
50.000 simultaneous calls 2.500.000 BHCA

HLR 2.400.000 subscribers 800.000 telemetric subs. SRR 56.000.000 entries 20.000 queries/s 30.000 STP msg/s 1.504 SS7 links
For internal use 29 Nokia Siemens Networks

HLR 3.750.000 subscribers 1.250.000 telemetric subs. SRR Next applicable release: M14

HLR 5.000.000 subscribers SRR 56.000.000 entries 40.000 queries/s 90.000 STP msg/s 1.952 SS7 links

DX200 Platform.ppt / ET / 08-2007

Nokia MSCi Capacity Roadmap


M13.0
Mechanics: Forced ventilation M98 Capacity when number of subscribers are maximized Nokia Default Traffic Profile Subscribers BHCA SMS/BH Subscribers BHCA SMS/BH Subscribers BHCA SMS/BH Simultaneous Calls Erlangs HW Configuration Mechanics: Basic M98 CPU Message Bus 800.000 600.000 550.000 600.000 600.000 1.000.000 400.000 1.000.000 230.000 ETSI: 20.800 ANSI: 16.000 ETSI: 16.700 ANSI: 12.800 CP710-A* MBIF-B

M13.2
1.200.000 1.000.000 1.200.000 1.000.000 1.000.000 1.500.000 400.000 1.200.000 1.500.000 ETSI: 20.800 ANSI: 16.000 ETSI: 16.700 ANSI: 12.800 CP710-A/CP816A** MBIF-C

M14
1.200.000 1.000.000 1.200.000 1.000.000 1.000.000 1.500.000 400.000 1.200.000 1.500.000 ETSI: 20.800 ANSI: 16.000 ETSI: 16.700 ANSI: 12.800 CP710-A/CP816A** MBIF-C

Capacity when number of calls are maximized Applicable to all traffic profiles

Capacity same as in Forced ventilation M98 mechanics HW Configuration CPU Message Bus CP550 MBIF-B CP550/CP816-A** MBIF-C CP550/CP816A** MBIF-C

* In new deliveries, not mandatory to upgrade in existing NE ** CP816-A needed in some functional units
For internal use 30 Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007

Nokia Transit MSCi Capacity Roadmap


M13.0 Mechanics: Forced ventilation M98 Capacity for pure transit traffic Capacity for pure gateway traffic Applicable to both transit and gateway traffic profiles HW Configuration Mechanics: Basic M98 Transit traffic Gateway traffic BHCA SMS/BH BHCA SMS/BH Simultaneous Calls Erlangs CPU Message Bus BHCA SMS/BH BHCA SMS/BH 1.400.000 4M 1.200.000 4M ETSI: 24.700 ANSI: 18.900 ETSI: 20.000 ANSI: 15.000 CP710-A** MBIF-B 1.200.000 600.000 1.000.000 300.000 M14 1.400.000 4M 1.200.000 4M ETSI: 24.700 ANSI: 18.900 ETSI: 20.000 ANSI: 15.000 CP710-A** MBIF-B 1.200.000 600.000 1.000.000 300.000

Values for Simultaneous Calls and Erlangs same as in forced ventilation M98 mechanics HW Configuration Message Bus MBIF-B MBIF-B

** In new deliveries, not mandatory to upgrade in existing NE


For internal use 31 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Nokia Compact MSCi Capacity Roadmap

M13.0 Mechanics: Forced ventilation M98 Capacity Subscribers BHCA SMS/BH Simultaneous Calls Erlangs HW Configuration CPU Message Bus 200.000 200.000 330.000 ETSI: 5.000 ANSI: 3.800 ETSI: 4.000 ANSI: 3.000 CP710-A** MBIF-B

M14 200.000 200.000 330.000 ETSI: 5.000 ANSI: 3.800 ETSI: 4.000 ANSI: 3.000 CP710-A** (or newer) MBIF-B

Mechanics: Basic M98

Capacity same as in Forced ventilation M98 mechanics HW Configuration Message Bus MBIF-B MBIF-B

** In new deliveries, not mandatory to upgrade in existing NE

For internal use 32 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Nokia Standalone MSS Capacity Roadmap

M13.0 Capacity when number of subscribers are maximized Subscribers BHCA SMS/BH Subscribers BHCA SMS/BH Simultaneous Calls CPU Message Bus 1.000.000 1.000.000 1.000.000 1.000.000 1.000.000 1.000.000 41.500 CP710-A/CP816A** MBIF-C

M13.2 1.500.000 1.200.000 900.000 1.200.000 1.200.000 1.200.000 41.500 CP710-A/CP816A** MBIF-C

M14 3.000.000 2.500.000 2.000.000 2.500.000 2.500.000 2.500.000 80.000 CP816-A EMB*

Nokia Default Traffic Profile

Applicable to all traffic profiles HW Configuration

* EMB upgradeable also to existing installations ** CP816-A needed in some functional units

For internal use 33 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Nokia Standalone MSS Capacity Roadmap


Gateway Mode

M13.0
Capacity BHCA Simultaneo us Calls CPU Message Bus 2.000.000 60.000 CP710-A (or newer) MBIF-C

M13.4
3.000.000 60.000 CP710-A (or newer) MBIF-C

M14
3.500.000 80.000 CP816-A EMB

HW Configurati on*

MSS in Gateway Mode No subscribers

For internal use 34 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Nokia Integrated MSS Capacity Roadmap


M13.0 Capacity when number of subscribers are maximised Nokia default traffic profile Subscribers BHCA SMS/BH 1.000.000 1.000.000 1.000.000 M13.2 1.500.000 1.000.000 750.000 M14 1.500.000 1.000.000 750.000

Subscribers BHCA SMS/BH Simultaneous Calls

1.000.000 1.000.000 1.000.000 36.000

1.100.000 1.100.000 1.100.000 36.000

1.100.000 1.100.000 1.100.000 36.000

Mechanics: Forced ventilation M98

Applicable to all traffic profiles HW Configuration

CPU Message Bus Subscribers BHCA SMS/BH Simultaneous Calls

CP710-A** MBIF-C 600.000 600.000 1.000.000 20.800

CP816-A MBIF-C 600.000 600.000 1.000.000 20.800 CP550-B** MBIF-C*

CP816-A MBIF-C 600.000 600.000 1.000.000 20.800 CP550-B** MBIF-C

Mechanics: Basic M98

Capacity

HW CPU CP550-B** Configuration * MBIF-C required if more than 50% of Message Bus 3G MBIF-C* subscribers are subscribers ** CP816-A needed in some functional units
For internal use 35 Nokia Siemens Networks DX200 Platform.ppt / ET / 08-2007

Nokia CDS Capacity Roadmap

M13.0 Capacity Simultaneous Data Calls ETSI: 1792 ANSI: 1536

M14 ETSI: 1792 ANSI: 1536

HW Configuration

CPU Message Bus

CP710-A (or newer) MBIF-B

CP710-A (or newer) MBIF-B

For internal use 36 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Nokia HLRi Capacity Roadmap


M13.0 Mechanics: Forced ventilation M98 Capacity Subscribers Telemetric Subscribers EIR IMEI entries: Black Gray White (ranges) CPU Message Bus RAM (GByte) in HLRU Mechanics: Basic M98 Capacity Subscribers Telemetric Subscribers EIR IMEI entries: Black Gray White (ranges) CPU Message Bus RAM (GByte) in HLRU 3.750.000 1.250.000 10.000.000 4.000.000 200.000 CP710-A (or newer**) MBIF-C 2 2.400.000 800.000 10.000.000 4.000.000 200.000 CP816-A MBIF-B 1.5 2.400.000 800.000 10.000.000 4.000.000 200.000 CP816-A MBIF-B 1.5 M14 5.000.000

10.000.000 4.000.000 200.000 CP816-A MBIF-C or EMB* 2

HW Configurat ion

HW Configurat ion

For internal use 37 Nokia Siemens Networks

* EMB in new deliveries only (M98A mechanics) ** In new deliveries, not mandatory to upgrade in existing NE
DX200 Platform.ppt / ET / 08-2007

Nokia SRRi Capacity Roadmap


M12 Mechanics: Forced ventilation M98 Capacity Entries Queries/sec * STP messages/sec * 56.000.000 20.000 30.000 M14 56.000.000 50.000 40.000 (TDM) or 90.000 (Sigtran) 1.952 CP816-A EMB 56.000.000 20.000 30.000 1.504

1.504 SS7 links HW Configurati on Mechanics: Basic M98 Capacity CPU Message Bus Entries Queries/sec * STP messages/sec * SS7 links CPU Message Bus CP710-A** MBIF-B 56.000.000 20.000 30.000 1.504

HW Configurati on

CP550-B MBIF-B

CP550-B MBIF-B

* These are maximum capacities for queries or STP messages (eg. In M12 max 20 000 queries/sec without STP messag ** In new deliveries, not mandatory to upgrade in existing NE
For internal use 38 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Nokia MGW Capacity Roadmap

U3 Port Capacity* E1 T1 IP ports ATM ports BHCA Simultaneous Calls Signal Processing Unit CPU 1.260 (20 x STM1) 1.680 (20 x OC3) 10.000 27.000 900.000 (U3B) 15.000 CDSP-C CCP10

U4 2.520 (40 x STM1) 3.360 (40 x OC3) 120.000 100.000 2.500.000 50.000 CDSP-D CCP18

U5 3.780 (60 x STM1) 5.040 (60 x OC3) 120.000 100.000 2.500.000 50.000 To be defined

Call Handling Capacity** HW Configurat ion

* Different port capacities are partly mutually exclusive since different interface types share partly same Plug In Unit s ** Total throughput capacity is dependent on the used call profile and interfaces

For internal use 39 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

Nokia CS Core Capacity Roadmap


Evolution Roadmap - Subrack Capacity (M90)

M13
MSC
150.000 subscribers 150.000 BHCA

M14
Not supported

T-MSC
10.000 Erlangs Pure Transit:

450.000 BHCA Gateway: 400.000 BHCA HLR


300.000 subscribers

HW Configuration
No new HW

For internal use 40 Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

41

Nokia Siemens Networks

DX200 Platform.ppt / ET / 08-2007

You might also like