HUAWEI Confidential

This course describes the main function and features of BSC6000V900R008, hardware structure and system principle of TC/BM separated system, including board module functions, system operating principles, system signal flows, etc.. In addition, the recommended typical configurations are listed (TC/BM separated & combination model) .

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 2

After learning this course, you should understand the following points:

BSC6000V900R008 function and features Hardware structure and system principle of TC/BM separated & combination system

Typical configuration of TC/BM separated & combination system

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 3

HUAWEI BSC6000V900R008 Product Description HUAWEI BSC6000V900R008 Hardware Description HUAWEI BSC6000V900R008 Features Description

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 4

Chapter 1 BSC6000V900R008 System Description

Chapter 2 BSC6000V900R008 Hardware Structure


Chapter 3 BSC6000V900R008 System Signal Flow Chapter 4 BSC6000V900R008 Typical Configuration

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 5

BSC6000 Roadmap
V9R8C01 V9R3C01 Abroad V9R1C04 Domestic

V9R1C01

V9R1C03

2007.02

2007.06

2007.09 R3

2007.12 R8

R1

V9R1C01 is the first business version of BSC6000 V9R1C03 enhances the BSC performance, such as intelligent power reduction, supporting new BTS types, etc.

GOMU MML Command Optical Port Backup Local Switching Flex Abis

Built-in PCU GBSS IP Solution Abis Over HDLC TC/BM combined configuration Distributed BTS is supported QTRU is supported

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 6

BSC6000V9R8 Specification Description


V9R8 Specification Items TRX Number (FR) TRX Number (HR) V9R1 V9R3 BM/TC Separated BM/TC Combined A Interface Over IP 2048 2048 1024 2048 2 4 2048 2048 24 15360 14 14 576 18 512 8 224 7 2048/1792 2048/1792 1 15360 14 NA 576/352 18/11 448 8 128 4 2048 2048 1 15360 14 NA 576 18 NA NA 224 7

Full Configuration Cabinet Number 34 A Interface Circuits GxPS Subrack Number GTCS Subrack Number Abis Interface E1Number Abis Interface STM-1Number A Interface E1Number A Interface STM-1Number Pb Interface E1 Number Pb Interface STM-1Number Gb Interface Throughput

15360 15360 14 14 640 20 512 8 224 7 NA 1 4 1 4 576 18 512 8 224 7 NA

256Mbps/512Mbps 256Mbps/512Mbps 256Mbps/512Mbps

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 7

Function and Features of BSC6000V9R8


BSC6000 system with external GBAM is defined as Configuration A and the BSC using built-in GOMU is defined as configuration B. Built-in PCU is supported, while former external PCU is also supported. A interface over IP. Abis interface transmission optimization.

Abis interface over HDLC Abis interface over IP

Hub BTS of HDLC transmission mode (Abis Interface Transmission Optimization ). TC/BM combined and separated configuration Um interface soft synchronization Support Distributed Base Station DBS3900 Support QTRU Support dynamic transmit diversity (PBT)

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 8

High Integration: A single cabinet can support 2048 TRXs

+
V900R001/V900R003

=
PCU6000

BSC6000V900R008

Full capacity: 2048TRXs 4 cabinets

External PCU

Full capacity: 2048TRXs One single cabinet Built-in PCU

4BM+4TC

2048TRXs can be supported by one single BSC6000V900R008 cabinet and built-in PCU can be integratedwhich can save much space of central equipment room. Power consumption will decrease a lot because of high integration. Typical power consumption of TC/BM combined full configuration is 3340W when E1 transmission is used on A/Abis interface, and 2325W, when STM1 is used on A Interface and E1 is used on Abis Interface.
HUAWEI Confidential
Page 9

HUAWEI TECHNOLOGIES Co., Ltd.

More Flexible Configuration: Separated and Combined BM/TC


BM/TC Separated BM/TC Combined

+
GTCS GMPS/GEPS Ater Interface boards are needed.

=
GMPS/GEPS

DPUa and DPUc can be used together, configured as GDPUC and GDPUX Ater interface boards

Logical DPU board must be GDPUX where physical board is DPUc No Ater interface boards

When BSC and MSC are located in the same equipment room, combined BM/TC is recommended, i.e., GTCS is not needed, so the configuration is more flexible. When BSC and MSC are in different equipment rooms, separated BM/TC with remote TC will be used.
HUAWEI Confidential
Page 10

HUAWEI TECHNOLOGIES Co., Ltd.

Capacity Specifications
Specification Maximum number of BTSs Maximum number of cells Maximum number of TRXs BHCA 2,048 2,048 2,048 3,500,000 Value

Maximum traffic volume


Maximum number of subscribers Maximum number of PDCHs can be configured Maximum number of TBFs supported by a PDCH Number of 16K timeslots on Abis Interface Throughput on Gb interface

13,000Erl
650,000 15,360 Uplink: 7 Downlink: 8 61,440 512Mbps

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 11

Engineering Specifications

BSC6000 Engineering Specifications


Spacification Cabinet standard Cabinet outline dimensions Available cabinet height Weight of the cabinet Load-bearing capability of the equipment room Value IEC60297 standard and IEEE standard. 2200mmHight*600mmWidth*800mmDepth 46U Empty cabinet 150kg; cabinet in full configuration 350kg 450kg/m2

Power Consumption Specifications

Typical Power Consumption Power Consumption Power Consumption Power configurati (Ater over STM-1, Abis (A over STM-1, Abis (A over E1, Abis over Consumption on over E1, Excluding the over E1, BM/TC E1, BM/TC (A over FE, GTCS) Combined) Combined) Abis over FE)
512TRX 1024TRX 1536TRX 2048TRX 700 1,080 1,360 1,530 890 1,510 1,950 2,325 1,325 2,320 3,250 3,340 890 1,510 1,950 2,325

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 12

Chapter 1 BSC6000V900R008 System Description

Chapter 2 BSC6000V900R008 Hardware Structure


Chapter 3 BSC6000V900R008 System Signal Flow Chapter 4 BSC6000V900R008 Typical Configuration

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 13

Abbreviation
Abbreviation

of Cabinet and Subrack


Full Name

Abbreviation

GBCR GBSR
GIMS GBAM GMPS GEPS GTCS

GSM BSC Control Processing Rack GSM BSC Service Processing Rack
GSM Integrated Management System GSM Back Administration Module GSM Main Processing Subrack GSM Extended Processing Subrack GSM TransCoder Subrack

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 14

Rack Structure

Cabinet Standard: The BSC6000 uses HUAWEI N68-22 cabinet, which is designed in compliance with the IEC60297 and IEEE standards.

Structure

Dimension: 600mm (width) x800mm (depth) x 2200mm (height) Weight: Empty rack 150kg; cabinet with full configuration 350kg

Type
The BSC6000 rack is categorized into two types:

GBCR: GSM BSC Control Processing Rack GBSR: GSM BSC Service Processing Rack

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 15

RackGBCR

GBCR: It must be configured with main processing subrack and GBAM server. It

Power Distribution Box

processes the BSC6000 services and


performs operations and maintenance.

Cabling Subrack

Subrack

Configuration A, GBCR consists of


GIMS 1GMPS must be included and 2Subracks at most Subrack

Air Defense Subrack

Configuration B, GBCR consists of

1GMPS+ 2GEPS(at most) KVM

GIMS:
One KVM (keyboard, video and mouse) One LAN Switch One GBAM (GSM Back Administration Module) server
In configuration B, the subrack containing GIMS is configured as GMPS.

Dummy Panel

Lan Switch

GBAM

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 16

RackGBSR

GBSR (GSM BSC Service Processing Rack ) It is only configured with subracks, no GBAM server in this rack. It performs service processing functions of the BSC6000.

Power distribution box

One service rack can be configured with three

Air defence subrack

subracks.

According to the requirement of service quantity, each BSC6000 system contains a maximum of three service racks.

subrack

Air defence subrack

Dummy panel
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 17

Subrack

Subrack: The subrack complies with


the IEC60297 standard. The width of it is 19 inches. A backplane is in the middle of the subrack, and boards are

Air Defense Box Board

inserted from the front and the rear of


the subrack. Both the front subrack and the rear subrack provide 14 slots respectively. The slots are numbered 0027 from the front to the rear.

Cabling subrack

Front

Rear

The BSC6000 contains three subracks:


GMPS: main processing subrack GEPS: extension processing subrack

GTCS: voice processing subrack


HUAWEI Confidential
Page 18

HUAWEI TECHNOLOGIES Co., Ltd.

Dip switch of Subracks

The DIP switches on the BSC subrack are used to define the numbering of the BSC subrack. The DIP bits are numbered in ascending order from bit 1 to bit 8. ON represents digit 0 and OFF represents digit 1. As the DIP switches use odd parity check, the number of 1s in the eight DIP bits must be an odd number. Set the DIP switch as follows: Set bits 1 5 and 8 first. Set bit 7 to 0. Check the number of 1s in the bits of the DIP switch. If the number of 1s is even, set bit 6 to 1. If the number of 1s is odd, set bit 6 to 0.

Bit 1 2 3 4 5 6 7

Meaning Subrack number setting bit Subrack number setting bit Subrack number setting bit Subrack number setting bit Subrack number setting bit Odd parity check bit Reserved, generally set to 0 The automatic DIP bit of the GSCU board in the central subrack. 0, the starting of boards is highly dependent on the GBAM server, namely that the boards load from the server after starting. 1, the starting of boards is less dependent on the GBAM server, namely that the boards check the validity of the Flash file when starting, and load from the Flash file if the Flash file is valid or load from the server if the Flash file is invalid.

ON

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 19

Hardware ConfigurationType A

BSC6000 Full ConfigurationTC/BM Separated, Local GTCS


E1/T1 transmission is used: GIMS+1 GMPS+2 GEPS+3 GTCS STM-1 is used on A interface : 1 GIMS+1 GMPS+2 GEPS+2 GTCS E1/T1 transmission GBCR GBSR GBSR STM-1 on A interface GBCR GBSR

GEPS

GTCS

GEPS

GTCS

GMPS

GTCS

GMPS

GTCS

GIMS

GEPS

GTCS

GIMS

GEPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 20

Hardware ConfigurationType A

BSC6000 Full ConfigurationTC/BM Separated, Remote GTCS


E1/T1 transmission is used : 1 GIMS1 GMPS2 GEPS3 GTCS STM-1 is used on A interface : 1 GIMS1 GMPS2 GEPS 2 GTCS E1/T1 transmission STM-1 on A interface GBSR GBCR GBSR GBSR

GBCR

GBSR

GEPS

GTCS

GEPS

GMPS

GTCS

GMPS

GTCS

GIMS

GEPS

GTCS

GIMS

GEPS

GTCS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 21

Hardware ConfigurationType B

BSC6000 Full ConfigurationTC/BM Separated, Local or Remote GTCS


E1/T1 transmission is used : 1 GMPS2 GEPS3 GTCS STM-1 is used on A interface : 1 GMPS2 GEPS 2 GTCS E1/T1 transmission GBCR GBSR

STM-1 on A interface
GBCR GBSR

GEPS

GTCS

GEPS

GEPS

GTCS

GEPS

GTCS

GMPS

GTCS

GMPS

GTCS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 22

System Logical Structure

The BSC6000 system consists of the following logical functional


subsystems:

TDM Switching Subsystem GE Switching Subsystem

Service Control Subsystem Interface and Signaling Processing Subsystem

Service Processing Subsystem Clock Subsystem

TDM switching subsystem

Service processing subsystem

Service control subsystem

Interface and signaling processing subsystem

E1/STM-1 to BTS E1/STM-1 to PCU E1/STM-1 to MSC Clock subsystem

GE switching subsystem

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 23

TDM Switching Subsystem

Intra-Subrack: Other boards in the subrack connect with GTNU (Active/Standby) through LVDS (Low Voltage Differential Signal) high speed serial ports of backplane.

Inter-Subrack: TDM units of every subrack fully interconnected with each other through GTNU crossover cables.

Board

GTNU Active GTNU Standby

GTNUActive

Board

Board

GTNU Standby

Board

LVDS TDM path of backplane Inter-GTNU Cable


HUAWEI TECHNOLOGIES Co., Ltd.

In full intra-subrack interconnection, 2 cables support 8K bandwidth.

HUAWEI Confidential

Page 24

BoardGTNU

GTNU

The GTNU is the TDM switching unit in the BSC6000. The active GTNU and the standby GTNU are inserted in slot 4 and slot 5 of the GMPS/GEPS/GTCS. The GTNU board performs the TDM switching function, which is the TDM switching center of the system.

RUN ALM ACT

The GTNU has the following functions:


TNM0

Providing 128 K 128 K TDM switching Allocating TDM network resources, establishing, and releasing radio links

TNM4

TNM3

TNM2

TNM1

Matching Port Function


connector DB14 TDM05 TDM high-speed serial port, used to connect the GTNUs between subracks

PARC

HUAWEI TECHNOLOGIES Co., Ltd.

TNM5

HUAWEI Confidential

Page 25

Inter-Subrack Interconnections of GTNU Crossover Cables


Pin14 A W1 Pin1 A X2 X1 W2 W4 X4 W3 X3 Pin14 B 1 2 3 Pin1 B

0
GTNU GTNU

1
GTNU GTNU

2
GTNU GTNU

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 26

GE Switching Subsystem

Intra-subrack active/standby GSCU boards: HiG interconnection; 30G bandwidth. Intra-subrack GE switching: The GSCU board provides 48G GE switching capability through backplane. Inter-subrack GE switching: The GSCU boards are connected in star topology through intercross cable using the GE ports on GSCU.

Board GSCU (Active) GSCU (Standby) Board

Board

GSCU (Active)
GSCU (Standby) Board

GE of Rear Intercross Cable

Star interconnection between subracks, four cable realize Active/Standby model


HUAWEI Confidential
Page 27

HUAWEI TECHNOLOGIES Co., Ltd.

BoardGSCU

SCUa

RUN ALM ACT RESET


LINK ACT

The GSCU is the switching control unit in the BSC6000. The active and standby GSCU are inserted in slot 6 and 7 of the GMPS/GEPS/GTCS. The GSCU board provides maintenance management of the subrack and GE switching platform for the subrack. The GSCU has the following functions:

0 1 2 3

Performing maintenance management of the subrack Providing a GE platform for the subrack Providing clock information for the other boards in the same subrack except the GGCU

LINK ACT

4 5

6 7
LINK ACT

10/100/1000BASE-T

Port EHT09 EHT1011

Function 10M/100M/1000M Ethernet ports, used to connect subracks 10M/100M/1000M Ethernet ports, used to connect GBAM (Only the main subrack is connected with the GBAM)

Matching RJ45 RJ45

8 9 10 11

RJ45
COM

COM

Debugging port Clock source port, used to receive the 8 kHz clock signals from the panel of the GGCU Clock test signal port, used to output clock test signals SMB connector RJ45

CLKIN

CLKIN
TESTOUT

TESTOUT
PARC

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 28

GE Switching Interconnection
GSCU in GMPS
GE 0

GSCU in GMPS

GE0/1: Idle GE27 interconnect with GEPS GE8/9 interconnect with main

GE TRUNK1
GE 1

GE TRUNK2

GE 2 GE 3

GE 0 GE 1

1#GEPS

GTCS

2#GEPS

GE 4

GE 0
GE 1

GE10/11 interconnect with GBAM

GE TRUNK3
GE 5

GSCU in GEPS

GE TRUNK4

GE 6 GE 7

GE 0 GE 1

GE0/1 interconnect with GMPS

3#GEPS

GE 8

GE 0 GE 1

GE TRUNK4
GE 9

Main GTCS

GE TRUNK5

GE 10

GBAM

LMT

GE TRUNK6 CPU FE

GE 11

M2000
FE

LanSwitch
HUAWEI Confidential
Page 29

HUAWEI TECHNOLOGIES Co., Ltd.

Interconnection Between Subrack


A interface

GTCS

GTCS
Pb interface Ater interface GEPS

GTCS

TC Abis interface

GMPS

GEPS

BM

Subracks of BSC6000 compose an interconnection switching network through cascade.


GSCU Star interconnection GTNU Full interconnection

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 30

Service Processing Subsystem

Hardware entity of service processing subsystem are DPUa/ DPUc/ DPUd boards:

DPUa board can only be used in GTCS and configured as DPUC, and it cannot be used in TC/BM combined configuration. DPUc board is configured as DPUX both in BM/TC combined and separated configuration. DPUd board processes built-in PCU packet service and is configured as GDPUP; In separated configurationDPUa and DPUc can be used together and configured as GDPUC and GDPUX respectively. Note: V9R1/V9R3 only support DPUa, which is configured as GDPUC
Recommended to be blank for future upgrade

GTCS

GMPS/GEPS
20 21 G O M U 22 23 G O M U 24 25 26 27 G E I U B G E I U B G E I U B G E I U B

R e a r
F r o n t

14 15 16 G O I U T

17 18 19 G O I U T

20 21 G G G E E O I I M U U U A A

22 23 G G G E E O I I M U U U A A

24 25 26 27 G E I U A G E I U A G E I U A G E I U A

R e a r
F r o n t

14 15 16 G E P U G G E P U G G O I U T

17 18 19 G O I U T

Backplane
G T N U G T N U G S C U G S C U G D P U X G D P U X G D P U X G D P U X G D P U X

Backplane
G X P U M G X P U M G X P U T G X P U T G T N U G T N U G S C U G S C U G D P U P G D P U P

00 01 02 03 04 05 06 07 08 09 10 11 12 13

00 01 02 03 04 05 06 07 08 09 10 11 12 13

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 31

BoardGDPUX/ GDPUC

DPUa

RUN ALM ACT

GDPUX / GDPUC process CS services and are configured in 00~03 or 08~13, boards perform the voice coding and decoding function. It works as subrack resource pool mode. GDPUX / GDPUC perform function as follows:

Provides Tandem Free Operation (TFO) functions, When the calling and called MSs use one voice coding scheme, the voice signals are encoded only once at the originating MS and decoded only once at the terminating MS. This reduces repeated encoding and decoding and

improves the quality of speech services.


Provides voice enhancement function Detects voice faults automatically

GDPUX is configured in BM:

Provides format conversion for 3740 IP speech paths and HDLC


optimized speech paths as well as data forwarding.

PARC

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 32

BoardGDPUP
DPUa

RUN ALM ACT

The GDPUP is the GSM Data Processing Unit for PS services. It can be installed in slots 811 in GMPS and 8-27 in GEPSit processes the packet services for the BSC. GDPUP is configured when PCU is inner. GDPUP performs the following function:

Each GDPUP supports 1024 activated PDCHs at the same time, and all the PDCHs support MSC-9 coding. Packet links processing function.

PS fault self-detection.

GDPUP works as system resource pool.

PARC

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 33

Service Control Subsystem

The BSC service control subsystem performs the following functions: paging control, message management, channel assignment, BTS public service management, call control, packet service control, handover and power control, cell broadcast short message service, and TC resource pool management, etc.

The components of the BSC service control subsystem are as follows:


GXPUM GXPUT GBAM/GOMU GSCU boards in GTCS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 34

BoardGXPUM /GXPUT
GXPU

GXPUM /GXPUT

RUN ALM ACT

GXPUM is the main service processing board, which is

configured in slot 01 of GMPS/GEPS.

GXPUT is transmission processing unit and is configured in 23 slots of GMPS/GEPS. GXPUM/GXPUT have four built-in CPUs and processes the key services of the BSC.

LINK ACT

When the TRX number configured in a single subrack is


less than 256, GXPUT isnt necessary.

0 1 2 3

PARC

HUAWEI TECHNOLOGIES Co., Ltd.

10/100/1000BASE-T

HUAWEI Confidential

Page 35

BoardGXPUM /GXPUT

CPUs of XPU board are classified as CPU0,CPUX,CPUP


Name CPUs CPU0 CPU3 CPU1 CPU2 CPU0 CPU1 CPU2 Types CPU0 CPUP Function Algorithm, Resource Management, PS Signal Processing Built-in PCU Maintenance, Cell Broadcast

GXPUM

CPUX

CS Service and signal processing

GXPUT

CPU3

GMPS/GEPS in Configuration A
14 15 16 17 18 19 G O I U T 20 21 G O M U 22 23 G O M U 24 25 26 27 G E I U B G E I U B G E I U B G E I U B

GMPS/GEPS in Configuration B R e a r F r o n t
14 15 16 G E I U P G E I U P G O I U T 17 18 19 G O I U T 20 21 G O M U 22 23 G O M U 24 25 26 27 G E I U B G E I U B G E I U B G E I U B

R e a r
F r o n t

G E I U P

G E I U P

G O I U T

Backplane
G X P U M G X P U M G X P U T G X P U T G T N U G T N U G S C U G S C U G G C U G G C U

Backplane
G X P U M G X P U M G X P U T G X P U T G T N U G T N U G S C U G S C U G G C U G G C U

00 01 02 03 04 05 06 07 08 09 10 11 12 13

00 01 02 03 04 05 06 07 08 09 10 11 12 13

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 36

GBAM, GOMU Board

GBAM/GOMU performs the following function in BSC:

Provides configuration management, performance management, fault management,

security management, and loading management for the BSC.

As the OM center of the BSC, the GOMU enables the communication between the LMT and the other boards in the BSC. The GOMU features high computation speed and outstanding data processing capability.

Interfaces with the LMT/M2000 on behalf of the BSC GMPS of Configuration A GMPS of Configuration B
17 18 19 G O I U T 20 21 G O M U 22 23 G O M U 24 25 26 27 G E I U B G E I U B G E I U B G E I U B G E I U P G O I U T

R e a r F r o n t

14 15 16 G E I U P

R e a r F r o n t

14 15 16 G E I U P G E I U P G O I U T

17 18 19 G O I U T G E I U B G E I U B

20 21

22 23

24 25 26 27 G E I U B G E I U B

Backplane
G X P U M G X P U M G X P U T G X P U T G T N U G T N U G S C U G S C U G G C U G G C U

Backplane
G X P U M G X P U M G X P U T G X P U T G T N U
G T N U

G S C U

G S C U

G G C U

G G C U

00 01 02 03 04 05 06 07 08 09 10 11 12 13

00 01 02 03 04 05 06 07 08 09 10 11 12 13

GBAM
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 37

GBAM Interface

Power Button

CD Rom 10M/100M RJ45 NIC Automatic Adaptation Port

LCD Interface

KVM Interface

RJ45 NIC Interface RJ45 NIC


HUAWEI TECHNOLOGIES Co., Ltd.

RJ45

End
Page 38

DC Prot

HUAWEI Confidential

BoardGOMU

As the OM center of the BSC, the GOMUs are installed in slots 2023 in GMPS

and work in active/standby mode. The GOMU features high computation


speed and outstanding data processing capability .

The GOMU has the following functions:

Provides configuration management, performance management, fault management, security management, and loading management for the BSC. Interfaces to the LMT/M2000 on behalf of the BSC

(1) Screw (4) RUN LED (7) Reset button (10) ETH0 (Ethernet port) (13) COM port (16) OFFLINE LED

(2) Leaf spring (5) ALM LED (8) Shutdown button (11) ETH1 (Ethernet port) (14) VGA port (17) Hard disk

(3) Wrench (6) ACT LED (9) USB port (12) ETH2 (Ethernet port) (15) HD LED (18) Screw for fix the hard disk

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 39

Interface Processing Subsystem

Interface processing subsystem provides interfaces between BSC/BTS/NSS, and performs data link layer signal processing function.

Provide A/Abis/Pb/Ater/Gb interface


Support processing of cell broadcast service Support No.7 signal MTP processing CBC
Cb A

Abis

BTS

GMPS/ GEPS

Ater

GTCS BSC6000

MSC

Pb

Gb

PCU

Built-in or External PCU

SGSN

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 40

Interface Board
Physical Board A EIUa GEIUA GEIUB GEIUT GEIUP \ OIUa GOIUA GOIUB GOIUT GOIUP \ RINT EIUa OIUa PEUa FG2a GOUa 32 E1/T1 Interface 1 TDM over STM-1 32 Packet over E1/T1 Interface 8 Packet over FE or 2 Packet over GE Electrical Interface 2 Packet over GE Optical Port
HUAWEI Confidential
Page 41

PEUa \ GEHUB \ \ GEPUG

FG2a GFGUA GFGUB \ \ GFGUG

GOUa GGOUA GGOUB \ \ \ Interface

Abis
Ater Pb Gb

A/Abis/Pb A/Abis/Pb Abis/Gb A/Abis/Gb A/Abis

HUAWEI TECHNOLOGIES Co., Ltd.

BoardEIUa/OIUa

Interface boards GEIU / GOIU contain:

GEIUB/GOIUB for Abis Electrical Unit/ Optical Unit

GEIU

GOIU

RUN ALM ACT

RUN ALM ACT

GEIUP/GOIUP for Pb Electrical Unit/ Optical Unit GEIUT/GOIUT for Ater Electrical Unit/ Optical Unit GEIUA/GOIUA for A Electrical Unit/ Optical Unit

E1/T1(24~31)

Main function contain:


RX TX

EIUa provides 32E1 ports

LOS

E1/T1(8~15)

OIUa provides 1STM-1 interface, which bears 63E1 Supply remote GTCS maintenance link Provides Tributary Protection Switching (TPS) between the active and standby boards.
Interface Function E1/T1 port, used to transmit and receive E1/T1 signals on routes 07 2.048 MHz clock source output port, used to output the extracted line clock as the system clock source 2.048 MHz clock output port, used to output the testing clock of the system Matching connector DB44 SMB male connector SMB male connector

E1/T1(0~7)

E1/T1(16~23)

2M0

TESTOUT 2M1

TESTOUT 2M1

2M0

E1/T1(0 31) 2M01 TESTOUT

PARC

PARC

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 42

BoardFG2a

Main function:

8 10M/100M FE ports, thereinto 2 GE ports(0,4) Provides IP routing Provides the routing-based backup and load sharing Provides Tributary Protection Switching (TPS) between the active and standby boards

Physical Name

Logical Name

Value

GFGUA
FG2a GFGUB GFGUG Interface ID 10/100M 10/100/1000M 2M0 2M1 Type RJ45 RJ45

6144 voice circuit


384TRX, 100%(HR) 128M bps Gb throughput Function

The 10M/100M ports are used to transmit 10/100 Mbit/s signals The 10M/100M/1000M ports are used to transmit 10/100/1000 Mbit/s signals.
No use No use

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 43

BoardGOUa

Main function:

Provides two GE optical ports Provides IP routing Provides the routing-based backup and load sharing Provides Tributary Protection Switching (TPS) between the active and standby boards
Physical Name GOUa GOGUB Interface ID RX TX 2M0 2M1 LC/PC
HUAWEI Confidential

Logical Name GOGUA

Value 6144 voice circuit 384TRX, 100%(HR) Function Optical ports are used to receive and transmit optical signals. TX indicates the transmitting optical port and RX indicates the receiving optical port. No use No use
Page 44

Type

HUAWEI TECHNOLOGIES Co., Ltd.

BoardPEUa

Main function

Provides 32 E1/T1 ports Provides Tributary Protection Switching (TPS) between the active and standby boards

Physical Name
PEUa

Logical Name
GEHUB GEPUG

Value
384TRX, 100%(HR) 64M bps Gb throughput

Interface ID E1/T1(0~31) 2M0 2M1

Type DB44 SMB Male Connector SMB Male Connector

Function 031 E1/T1 for transmitting signal No use No use

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 45

Clock System
Time synchronization primary reference GGCU (Active/Standby) 0# subrack
Transmission synchronization reference source

Backplane

Distribution cable transmission

GSCU
Backplane

GSCU
Backplane

GSCU
Backplane

Board

Board

Board

Board

Board

Board

GMPS

GEPS

GEPS
Page 46

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

BoardGGCU

GGCU

RUN ALM ACT

The GGCU is the general clock unit in the BSC6000. The active GGCU and the standby GGCU are configured in slots 12 and 13 in the GMPS. The GGCU board provides synchronous timing signals for the system The GGCU has the following functions:

0 1 2 3 4 5 6 7 CLKOUT

Generating and keeping synchronous clock signals Keeping the consistency of synchronization information output from the active and standby GGCUs

Port CLKOUT09

Function Synchronization signal output port, used to output 8 kHz clock signals to the GSCU Standby Standby Standby Synchronization clock signal input port, used to input one route of external 2.048 MHz signal and 2.048 Mbit/s code stream signals

Matching Connector RJ45

8 9 COM0 COM1
CLKLIN0 TESTOUT

COM01 TESTOUT TESTIN CLKIN01

RJ45 SMB male connector SMB male connector SMB male connector

PARC

HUAWEI TECHNOLOGIES Co., Ltd.

CLKLIN1

TESTIN

HUAWEI Confidential

Page 47

Clock Subsystem

GGCU Reference Clock Input


To input the active-standby clock of the GGCU, you can use the signals provided by the BITS and the 2.048MHz clock signal extracted from the upper-level clock by the interface panel in the service subrack. The GGCU backplane uses the interface panel of the same subrack to extract the 8 KHz clock signals from the upper-level clocks.

Reference Clock for the GMPS or GEPS


The reference clocks are provided by the GGCU. The reference clocks generate 8kHz clock signals through the GGCU. GMPS: The clock signals are sent to the GSCU in the GMPS subrack through the backplane. Then, the clock signals are sent to other boards in the same subrack. GEPS: The clock signals are sent to the GSCU board in the GEPS subrack through the clock cable. Then, the signals are sent to other boards through the backplane.

Reference Clock for the GTCS


Each GTCS extracts line clock from the A interface. The line clock is processed through A interface panel and then generates 8 KHz clock signals. The clock signals are sent to the GSCU in the subrack through the backplane. Then the clock signals are sent to other boards in the same subrack.

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 48

Clock Synchronization Interconnection

The connection of the GGCU of the main subrack and the GSCU of the extension subrack is shown as following figure:
The active GGCU and the standby GGCU output 10-way signal channel respectively. A signal channel of an active GGCU and that of a standby GGCU are integrated through the Y-shaped cable. GGCU support six service subracks, one is the GMPS, others five are the GEPSs where the 10 cables from GSCUs to GGCU can be connected at most. Any of component including GGCU, Y-shaped cable, and GSCU is faulty, the system clock still can work normally. GEPS GMPS
GGCU GGCU
GSCU GSCU

Y Cable

HUAWEI TECHNOLOGIES Co., Ltd.

GEPS
GSCU GSCU

HUAWEI Confidential

Page 49

Clock Cable

1 W2

1
8 1

8 1

X2 W1 X1 W3 X3
8 1

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 50

Chapter 1 BSC6000V900R008 System Description

Chapter 2 BSC6000V900R008 Hardware Structure


Chapter 3 BSC6000V900R008 System Signal Flow Chapter 4 BSC6000V900R008 Typical Configuration

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 51

Voice Service Signal Flow

Abis over TDM+A over TDM

MS

BTS

G E I U B

G T N U

G E I U T
Ater

G E I U T

G T N U

Abis GMPS/GEPS

G D P U X

G E I U A

MSC A

GTCS

Front Board Rear Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 52

Voice Service Signal Flow

Abis over HDLC/IP+A over TDM

MS

BTS

G E H U B

G S C U

G D P U X

G T N U

G E I U T
Ater

G E I U T

G T N U

Abis GMPS/GEPS

G D P U X

G E I U A

MSC A

GTCS

Front Board Rear Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 53

Packet Service Signal Flow (External PCU)

Abis over TDM

When Abis interface is over HDLC/IP, BSC6000 doesnt support external PCU.

MS

BTS

G E I U B

G T N U
GMPS/GEPS

G E I U P
Pb

PCU Gb

SGSN

Abis

Front Board Rear Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 54

Packet Service Signal Flow (Built-in PCU)

Abis over TDM


G E I U B

MS

BTS

G T N U

G D P U P
GMPS/GEPS

G S C U

G E P U G
Gb

SGSN

Abis

Abis over HDLC/IP


G E H U B

MS

BTS

G S C U

G D P U P
GMPS/GEPS

G S C U

G E P U G
Gb

SGSN

Abis

Front Board Rear Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching


Page 55

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Abis Interface Signal

Abis interface board will be determined by the protocol on Abis interface:


Abis over TDM: GEIUB/GOIUB


Abis over HDLC: GEHUB Abis over IP: GFGUB GXPUT/GXPUM process LAPD and RR protocol

Signal processing flow:

GXPUM process BTSM protocol

MS

BTS

G S C U

Abis

G X P U T
GMPS/GEPS

G S C U

G X P U M

Abis Board

Front Board Rear Board


HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential

E1/T1 cable Backplane TDM Switching Backplane GE Switching


Page 56

No.7 Signal Flow


Through the processing of MTP2 model, it will be transmitted to GXPUM as internal signal.

G X P U M

G S C U

G E I U T
Ater

G E I U T

G T N U

G E I U A

MSC

GMPS/GEPS

GTCS

Front Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching

Rear Board

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 57

Ater Signal Flow


Through the processing of MTP2 model, it will be transmitted to GXPUM as internal signal.

G X P U M

G S C U

G E I U T
Ater

G E I U T

G S C U

GMPS/GEPS

GTCS

Through the processing of MTP2 model, it will be transmitted to GSCU as internal signal.

Front Board Rear Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching


Page 58

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Pb Signal Flow (External PCU)

The BSC internal signaling flow from the Pb interface is as follows:

The signaling is transmitted to the GXPUT/GXPUM in the GMPS/GEPS over the Pb interface. The GXPUT processes the signaling according to the LAPD protocol. Upon reception of the signaling from the GSCU, the GXPUM processes the signaling according to the PbIP and RR protocols. Through the processing of LAPD model, it will be transmitted to GXPUM as internal signal. G X P U M

G S C U
GMPS/GEPS

G E I U P
Pb

PCU Gb

SGSN

Front Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching


Page 59

Rear Board

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Gb Signal Flow (Built-in PCU)

The BSC internal signaling flow from the Gb interface is as follows:

The signaling is transmitted to the GMPS/GEPS over the Gb interface. If the sub NS layer of the NS protocol complies with the FR protocol, the Gb interface board is

the GEPUG. If the sub NS layer of the NS protocol complies with the IP protocol,
the Gb interface board is the GFGUG.

The GSCU transmits the signaling to the GXPUM. The GXPUM processes the signaling according to the NS and BSSGP protocols. G X P U M G S C U
GMPS/GEPS

G E P U G
Gb

SGSN

Front Board Rear Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching


Page 60

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Operation Maintenance Flow


HDLC Link
Service Board

L M T

O M U

G S C U

G E I U T

G E I U T

G S C U

Service Board

GMPS

Ater

GTCSRemote

Hardware is GBAM/GOMU G S C U

Service Board

E1/T1 cable Inter-Subrack Switching Backplane GE Switching

G S C U

Service Board

GEPS

GTCSLocal
Page 61

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Operation Maintenance Flow

GMPS OML Path:

LMTGBAMGSCUGMPS Subrack Boards LMT GBAM GSCU GSCU Intercross Cable GSCUGEPS Subrack Boards

GEPS OML Path:

GTCS Configuration OML Path:

GTCS Remote: LMT GBAM GSCUGEIUTHDLC GEIUT GSCU

GTCS Subrack Boards

GTCS Local: LMT GBAM GSCUIntercross CableGSCUGTCS Subrack Boards

BTS Configuration OML Path:

BTS is configured in GMPS: LMT GBAM GSCUGEIUBBTS

BTS is configured in GEPS: LMT GBAM GSCUGSCU Intercross Cable


GSCU GEIUBBTS
GMPS Board GEPS Board GTCS Board

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 62

Chapter 1 BSC6000V900R008 System Description

Chapter 2 BSC6000V900R008 Hardware Structure


Chapter 3 BSC6000V900R008 System Signal Flow Chapter 4 BSC6000V900R008 Typical Configuration

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 63

Hardware configuration Principle

Service processing boards

One single GDPUX/GDPUC supplies 960 voice circuits coding/decoding, GDPUX/ GDPUC work as resource pool in the subrack. One single GDPUX supports 3740 voice circuits frame conversion or transmission between IP/HDLC and TRAU. One single GDPUP provides a processing capability of 1024 MCS-9 PDCH channels and supports 1024 cells at most, GDPUP works as resource pool in whole system and could be inserted in rear slots. Number of GDPUP+GDPUX+GDPUC couldnt be more than 10.

GXPUM/GXPUT

GXPUM must be inserted in slot 0&1 of GMPS/GEPS fixedly;. GXPUT is inserted in slot 2&3 of GMPS/GEPS by requirement, when the number of TRX in same subrack is less than 256, GXPUT may not be configured.

Interface Specification

Abis: GEIUB/GOIUB supports 256TRXs (HR) at most, GEHUB/GFGUB/GOGUB also support 384TRX(HR)at most. Ater: GOIUT/GEIUT support 7168/3840 voice circuits at most. A: 5 groups of GOIUA/GEIUA can be configured per subrack at most. If A interface uses STM-1 transmission, at most 9600 CIC can be accessed in a single subrack.
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 64

Typical Configuration

512TRXs

Configuration A, External PCU, Remote GTCS, E1/T1 on A Interface, E1/T1 on Abis Interface Configuration B, External PCU, Remote GTCS, E1/T1 on A Interface, E1/T1 on Abis Interface Configuration A, Built-in PCU, Remote GTCS, E1/T1 on A Interface, E1/T1 on Abis Interface Configuration B, Built-in PCU, RemoteGTCS, E1/T1 on A Interface, E1/T1 on Abis Interface

1280TRXs

Configuration A, Built-in PCU, Remote GTCS, E1/T1 on A Interface, E1/T1 on Abis Interface Configuration B, Built-in PCU, Remote GTCS, E1/T1 on A Interface, E1/T1 on Abis Interface

Full Configuration 2048/1792 TRXs

Configuration B, External PCU, Remote GTCS, STM-1 on A Interface, E1/T1 on Abis Interface, 2048TRXs

Configuration B, Built-in PCU, GTCS Remote, STM-1 on A Interface, E1/T1 on Abis Interface,
2048TRXs Configuration A, External PCU, Remote GTCS, E1/T1 on A Interface, E1/T1 on Abis Interface, 1792TRXs

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 65

Typical Configuration 512TRX

External PCU

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 66

Typical Configuration 512TRX

Built-in PCU

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 67

Typical Configuration 1280TRX

1GMPS+1GEPS+2GTCS, Built-in PCU

GBAM

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 68

Typical Configuration 2048TRX


External PCU Built-in GOMU GOIUA is the A interface board

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 69

Typical Configuration 2048TRX


Built-in PCU Built-in GOMU GOIUA is the A interface board

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 70

Typical Configuration 1792TRX

GBAM

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 71

2008-05

Security Level: Internal Use

Appendix Difference in TC/BM combination mode

www.huawei.com

HUAWEI Confidential

Chapter I BSC6000V900R008 Hardware Structure Chapter II BSC6000V900R008 System Signal Flow Chapter III BSC6000V900R008 Typical Configuration

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 73

Hardware Configuration Type A

BSC6000 Full Configuration (TC/BM Combinationwithout GTCS)


E1/T1 are the interface transport model: 1 GIMS1 GMPS3 GEPS STM-1 is used in A interface :1 GIMS1 GMPS2 GEPS
E1/T1 as transport model A interface is optical

GBCR

GBSR

GBCR

GBSR

GEPS

GEPS

GMPS

GEPS

GMPS

GIMS

GEPS

GIMS

GEPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 74

Hardware Configuration Type A

BSC6000 Full Configuration (TC/BM Combinationwithout GTCS)


E1/T1 are the transport model : 1 GMPS3 GEPS STM-1 is used in A interface: 1 GMPS2 GEPS
E1/T1 as transport model A interface is optical GBCR

GBCR

GBSR

GEPS

GEPS

GEPS

GEPS

GMPS

GEPS

GMPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 75

GE Switching Interconnection
GSCU in GMPS
GE 0

GSCU in GMPS

GE TRUNK1
GE 1

GE0/1 : Idle GE27 interconnect with GEPS GE10/11 interconnect with GBAM

GE TRUNK2

GE 2 GE 3

GE 0 GE 1

1GEPS

GE 0
GE 1

GSCU in GEPS

GE 4

GE0/1 interconnect with GEPS

GE TRUNK3
GE 5

2GEPS

GE TRUNK4

GE 6 GE 7

GE 0 GE 1

3GEPS

GE 8

GE TRUNK4
GE 9

GE TRUNK5

GE 10

GBAM

LMT

GE TRUNK6 CPU FE

GE 11

M2000
FE

LanSwitch
HUAWEI Confidential
Page 76

HUAWEI TECHNOLOGIES Co., Ltd.

Interconnection Between Subrack


A interface

GEPS
Abis interface
MSC

Gb/Pb interface

GEPS

MS

BTS

SGSN

GMPS

Subracks in BSC6000 compose an interconnection switching network through cascade.


GSCU Star interconnection GTNU Full interconnection

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 77

Service Processing Subsystem

Hardware entity of service processing subsystem are DPUc/DPUd boards:


DPUa couldnt be used in V900R008 combination model; DPUc is configured as DPUX on combination model; DPUd board processes inner PCU packet service and is configured as GDPUP; acd physical version.
GMPS GEPS
22 23 G O M U 24 25 26 27 G E I U B G E I U B G E I U B G E I U B 14 15 16 G O I U A G O I U A G O I U A 17 18 19 G O I U A G O I U A G O I U A 20 21 G E I U B G E I U B 22 23 G E I U B G E I U B 24 25 26 27 G E I U B G E I U B G D P U X G D P U X G O M U

Note: DPUData Processing Unitis digital signal processing unit for PARC platform,

14 15 16
G O I U A G O I U A G O I U A

17 18 19 G O I U A G E P U G G E P U G

20 21

Rear

Rear

Backplane
G X Front P U M G X P U M G X P U T G X P U T G T N U G T N U G S C U G S C U G D P U P G D P U P G D P U X G D P U X G G C U G G C U

Backplane
G X Front P U M
G G G D D T P P N U U U P X 00 01 02 03 04 05 06 07 08 09 10 11

G X P U M

G X P U T

G X P U T

G T N U

G S C U

G S C U

G D P U P

G D P U P

G D P U X

G D P U X

00 01 02 03 04 05 06 07 08 09 10 11 12 13

12 13

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 78

BoardGXPUM /GXPUT

CPUs of XPU board are distributed as CPU0,CPUX,CPUP


Name CPUs CPU0 CPU3 CPU1 CPU2 CPU0 CPU1 CPU2 CPU Types CPU0 CPUP Function Algorithm, Resource Management, PS Signal Processing Inner PCU Maintenance, Cell Broadcast

GXPUM

CPUX

CS Service and signal processing

GXPUT

CPU3 GMPS
14 15 16 G O I U A G O I U A G O I U A 17 18 19 G O I U A G E P U G G E P U G 20 21 G O M U 22 23 G O M U 24 25 26 27 G E I U B G E I U B G E I U B G E I U B 14 15 16 G O I U A G O I U A G O I U A 17 18 19 G O I U A G O I U A G O I U A

GEPS
20 21 G E I U B G E I U B 22 23 G E I U B G E I U B 24 25 26 27 G E I U B G E I U B G D P U X G D P U X

Rear

Rear

Backplane
G X Front P U M G X P U M G X P U T G X P U T G T N U G T N U G S C U G S C U G D P U P G D P U P G D P U X G D P U X G G C U G G C U

Backplane
G X Front P U M
G G G D D T P P N U U U P X 00 01 02 03 04 05 06 07 08 09 10 11 G T N U G S C U G S C U

G X P U M

G X P U T

G X P U T

G D P U P

G D P U P

G D P U X

G D P U X

00 01 02 03 04 05 06 07 08 09 10 11 12 13

12 13

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 79

GBAM and GOMU Board

GBAM and GOMU finish the following function in BSC:

Provides configuration management, performance management, fault management, security management, and loading management for the BSC; As the OM center of the BSC, the GOMU enables the communication between the LMT and the other boards in the BSC. The GOMU features high computation speed and outstanding data processing capability. Interfaces with the LMT/M2000 on behalf of the BSC
Suggest to be empty for future upgrade GMPS
14 G O I U A G X P U M 00 15 G O I U A G X P U M 01 16 17 18 G G G O O E I I P U U U A A G G X P U T 02 G X P U T 03 19 20 21 22 23 G G G E O O P M M U U U G 24 25 26 G G G E E E I I I U U U B B B G D P U X 11 27 G E I U B 14 G O I U A G X P U M 00 15 G O I U A G X P U M 01 16 17 18 G G G O O E I I P U U U A A G G X P U T 02 G X P U T 03

GMPS
19 20 21 22 23 G E P U G 24 25 26 G G G E E E I I I U U U B B B G D P U X 11 27 G E I U B

Rear

Rear

Backplane

Backplane
G G D D P P U U P X 09 10 G G C U G G C U G G D T P N U U P 04 05 06 07 08 G T N U G S C U G S C U G G D D P P U U P X 09 10 G G C U G G C U

Front

G G D T P N U U P 04 05 06 07 08 G T N U G S C U G S C U

Front

12 13

12 13

GBAM

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 80

Chapter I BSC6000V900R008 Hardware Structure Chapter II BSC6000V900R008 System Signal Flow Chapter III BSC6000V900R008 Typical Configuration

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 81

Voice Service Signal Flow

Abis over TDM+A over TDM


A Board is GEIUA/GOIUA

MS

BTS

G E I U B

G T N U

Abis

G D P U X

G E I U A

MSC A

GMPS/GEPS

Abis Board is GEIUB/GOIUB

Front Board Rear Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 82

Voice Service Signal flow

Abis Over HDLC/IP+A Over TDM


A interface board is GEIUA/GOIUA

MS

BTS

G E H U B

G S C U

Abis

G D P U X
GMPS/GEPS

G T N U

G E I U A

MSC A

When Abis is Over IP, interface board is GFGUB/GOGUB Front Board Rear Board E1/T1 cable

Backplane TDM Switching Backplane GE Switching

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 83

No.7 Signal Flow

Through the processing of MTP2 model, it will be transmitted to GXPUM as intra-signal;

G X P U M

G S C U
GMPS/GEPS

G E I U A

MSC

Front Board Rear Board

E1/T1 cable Backplane TDM Switching Backplane GE Switching

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 84

Operation Maintenance Flow

L M T

O M U

G S C U

Service Board

GMPS
Hardware is GBAM/GOMU

G S C U
E1/T1 cable Backplane TDM Switching Backplane GE Switching
HUAWEI TECHNOLOGIES Co., Ltd.

Service
Board

GEPS

HUAWEI Confidential

Page 85

Operation Maintenance Flow

GMPS OML Path:

LMT-GBAM/GOMU-GSCU-GMPS Subrack Boards

GEPS OML Path:

LMT-GBAM/GOMU-GSCU-GSCU Intercross cable-GSCU-GEPS Subrack Boards

BTS Configuration OML Path:

BTS is configured in GMPS LMT-GBAM/GOMU-GSCU-GEIUB-BTS

BTS is configured in GEPS LMT-GBAM/GOMU-GSCU-GSCU Intercross cable-GSCU-GEIUB-BTS

The OML flow in this page just should be used in Abis Over TDM

GMPS Board

GEPS Board

GTCS Board

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 86

Chapter I BSC6000V900R008 Hardware Structure Chapter II BSC6000V900R008 System Signal Flow Chapter III BSC6000V900R008 Typical Configuration

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 87

Hardware configuration Principle

Service processing boards

Single GDPUX supplies 960 voice circuits coding/decoding, it works as resource pool in subrack. If just need 1 board, we can configed as 2 boards, Otherwise do not config as N+!. DPUX supports 3740 voice circuits frame conversion or transmission between TRAU/IP/HDLC and TRAU, We can config as N+! Mode. Single GDPUP supplies 1024 MCS-9 PDCH channel of processing packet service, supports 1024 cells at most, GDPUP is resource pool of whole system and could be inserted in rear slots; Number of GDPUP+GDPUX+GDPUC couldnt be more than 10;

GXPUM/GXPUT

GXPUM must be inserted in 0&1 slots of GMPS/GEPS fixedly; GXPUT is inserted in 2&3 slots of GMPS/GEPS by requirement, when the TRX of current subrack is less than 256, CXPUT may not be configured, if needs, its certainly;

Interface Specification

Abis: GEIUB/GOIUB support 256TRX(HR)at most, GEHUB GFGUB/GOGUB also support 384TRX(HR)at most; A: GOIUA/GEIUA are configured 5 groups per subrack at most, if A interface uses optical transport, single subrack could access 9600 CIC at most;
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 88

Typical Configuration

512TRX

Configuration A, Outer PCU, A Interface Optical, Abis Interface E1/T1 Configuration A, Inner PCU, A Interface Optical, Abis Interface E1/T1 Configuration B, Outer PCU, A Interface Optical, Abis Interface E1/T1 Configuration B, Inner PCU, A Interface Optical, Abis Interface E1/T1

1280TRX

Configuration A/B, Outer PCU, A Interface Optical, Abis Interface E1/T1 Configuration A/B, Inner PCU, A Interface Optical, Abis Interface E1/T1

Full Configuration 2048TRX


Configuration A, Outer PCU, A Interface Optical, Abis Interface E1/T1 Configuration B, Outer PCU, A Interface Optical, Abis Interface E1/T1 Configuration A, Inner PCU, A Interface Optical, Abis Interface E1/T1 Configuration B, Inner PCU, A Interface Optical, Abis Interface E1/T1

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 89

Typical Configuration 512TRX

Outer PCUA interface uses STM-1 as transport model, Abis interface uses E1/T1 as transport model, supports 512TRX at most.

Left: configuration
A:1GIMS+1GMPS Right: configuration B,1GMPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 90

Typical Configuration 512TRX

Inner PCUA interface uses STM-1 as transport model, Abis interface uses E1/T1 as transport model, supports 512TRX at most.

Left: configuration A
1GIMS+1GMPS Right: configuration B,1GMPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 91

Typical Configuration 1028TRX

Outer PCUA interface uses STM-1 as transport model, Abis interface uses E1/T1 as transport model, supports 1028TRX at most.

Leftconfiguration A

1GIMS+1GMPS+1GEPS

Rightconfiguration B,1GMPS+1GEPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 92

Typical Configuration 1028TRX

Inner PCUA interface uses STM-1 as transport model, Abis interface uses E1/T1 as transport model, supports 1280TRX at most.

Leftconfiguration A
1GIMS+1GMPS+1GEPS Rightconfiguration B,1GMPS+1GEPS

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 93

Typical Configuration 2048TRX

Configuration: 1GIMS+1GMPS+2GEPS Supports 2048TRX at most.


Configuration A, Outer GBAM Outer PCU

A interface uses STM-1 as


transport model Abis interface uses E1/T1 as transport model

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 94

Typical Configuration 2048TRX

Configuration: 1GIMS+1GMPS+2GEPS Supports 2048TRX at most.


Configuration B, Inner GOMU Outer PCU

A interface uses STM-1 as


transport model Abis interface uses E1/T1 as transport model

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 95

Typical Configuration 2048TRX

Configration:1GIMS+1GMPS+ 2GEPS Support 2048TRX


Configuration A, Outer GBAM Inner PCU

STM-1 is A interface physical


transport E1/T1 is Abis interface physical transport

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 96

Typical Configuration 2048TRX

Configuration:1GIMS+1GMPS+

2GEPS

Supports 2048TRX

Configuration B Inner GOMU Inner PCU STM-1 is A interface physical transport E1/T1 is Abis interface physical transport

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 97

Abbreviation

Cabinet and Subrack Abbreviation


English Abbreviation GBCR GBSR GBAM GMPS GEPS GTCS English Full Name GSM BSC Control Processing Rack GSM BSC Service Processing Rack GSM Back Administration Module GSM Main Processing Subrack GSM Extended Processing Subrack GSM TransCoder Subrack

Boards Abbreviation Collection


Physical OMUb GCUa SCUa TNUa XPUa Logical GOMU GGCU GSCU GTNU English Full Name GSM Operation Maintenance Unit GSM General ClocK Unit GSM Switching and Control Unit GSM TDM switching Network Unit GSM extensible Processing Unit for Main service GSM extensible Processing Unit for Transmission

GXPUM
GXPUT

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 98

Abbreviation
Physical DPUa DPUc DPUd Logical GDPUC GDPUX GDPUP GEIUB EIUa GEIUP GEIUT English Full Name GSM Data Processing Unit for CS service GSM Data Processing Unit for eXtensible service GSM Data Processing Unit for PS service GSM E1/T1 Interface Unit for aBis GSM E1/T1 Interface Unit for Pb GSM E1/T1 Interface Unit for aTer

GEIUA
GOIUB OIUa GOIUP GOIUT GOIUA GFGUA FG2a GFGUB GFGUG GOUa GOGUA GOGUB GEHUB GEPUG

GSM E1/T1 Interface Unit for A


GSM Optic Interface Unit for aBis GSM Optic Interface Unit for Pb GSM Optic Interface Unit for aTer GSM Optic Interface Unit for A GSM Fast ethernet and Gigabit ethernet Unit for A GSM Fast ethernet and Gigabit ethernet Unit for aBis GSM Fast ethernet and Gigabit ethernet Unit for Gb GSM Optic Gigabit ethernet Unit for A GSM Optic Gigabit ethernet Unit for aBis GSM E1/T1 High level Data Link Control Unit for aBis GSM E1/T1 Packet Unit for Gb

PEUa

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 99

This course mainly introduces three points as following:


BSC6000 V900R008 New Function and Features BSC6000 V900R008 Hardware Structure and System Principle of TC/BM separated & combination mode;

BSC6000 V900R008 Typical Configuration while TC/BM is


separation & combination mode

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 100

Thank You
www.huawei.com

You might also like